Hyundai H-HI1-30-UI581 [5/52] Attention

Hyundai H-HI1-30-UI581 [5/52] Attention
5.
Gas forced heater
EN
Technical specications
Table 1
H-HI1-10-UI580 H-HI1-30-UI581 H-HI1-50-UI582
Nominal heat output
W 10000 30000 50000
Fuel Consumption kg/h 0,73 2,18 3,63
Fuel Orice Port Size mm 0,74 1,28 1,4
Air ow temperature oC 300 430 360
Gas type Propane/Butane Propane/Butane Propane/Butane
Gas category G30 G30 G30
Gas pressure mBar 300 700 1500
Air consumption m
3
/h 320 650 872
Rated voltage V/Hz ~220/50 ~220/50 ~220/50
Nominal power consump-
tion
W 30 70 70
Rated current A 0,14 0,32 0,32
Type of Ignition piezo piezo piezo
Noise level dB 60 63 65
Overheating Protection
o
C 95 75 95
Weight kg 3,8 6,1 6,8
Dimensions mm 305x380x190 360x475x225 360x580x225
Electrical protection class Class I Class I Class I
Moisture protection class IPx0 IPx0 IPx0
ATTENTION!
The manufacturer reserves the right to change the set-list of the
device (including liquid and powder components) for dierent
supplies without prior notice. The changes either in no way inuence
the basic technical parameters of the device or may improve them,
and also not violate the legislation or quality standards of the
countries of manufacture, transit and selling.
The changes in the set-list may result in changing of the weight
and dimensions of the device, but not more than by +\- 5-20%
(depending on the product category)
For more detailed description of technical parameters and specications please refer to our web-
site www.hyundai-hvac.com or ask from the ocial dealers of Hyundai.