Sencor SAC 1211CH [11/24] Wall mounted split air conditioner
Содержание
- Sac 0911 ch sac 1211ch 1
- User s manual 1
- Wall mounted split air conditioner z 1
- Contents 2
- Sac 0911 ch sac 1211 ch 2
- Wall mounted split air conditioner 2
- Important safety instructions read carefully and store for future use 4
- Sac 0911 ch sac 1211 ch 4
- Wall mounted split air conditioner 4
- Description of the air conditioning device 5
- Sac 0911 ch sac 1211 ch 5
- Wall mounted split air conditioner 5
- Description of the display 6
- Sac 0911 ch sac 1211 ch 6
- Wall mounted split air conditioner 6
- Description of the remote control 7
- Sac 0911 ch sac 1211 ch 7
- Wall mounted split air conditioner 7
- Sac 0911 ch sac 1211 ch 8
- Wall mounted split air conditioner 8
- Automatic timer controlled on off operation 9
- Sac 0911 ch sac 1211 ch 9
- Wall mounted split air conditioner 9
- Sac 0911 ch sac 1211 ch 10
- Setting the operating mode 10
- Wall mounted split air conditioner 10
- Sac 0911 ch sac 1211 ch 11
- Wall mounted split air conditioner 11
- Sac 0911 ch sac 1211 ch 12
- Wall mounted split air conditioner 12
- Sac 0911 ch sac 1211 ch 13
- Tilting the horizontal air flow direction adjustment flaps 13
- Wall mounted split air conditioner 13
- Emergency operation button 14
- Sac 0911 ch sac 1211 ch 14
- Wall mounted split air conditioner 14
- Cleaning and maintenance 15
- Cleaning the front panel and filters 15
- Sac 0911 ch sac 1211 ch 15
- Wall mounted split air conditioner 15
- Before putting the air conditioner out of operation for an extended period of time 16
- If you have not used the air conditioner for a long time 16
- Sac 0911 ch sac 1211 ch 16
- Wall mounted split air conditioner 16
- Sac 0911 ch sac 1211 ch 17
- Troubleshooting 17
- Wall mounted split air conditioner 17
- Sac 0911 ch sac 1211 ch 18
- Wall mounted split air conditioner 18
- Sac 0911 ch sac 1211 ch 19
- Technical parameters 19
- Wall mounted split air conditioner 19
- Installation instructions 20
- Locating the indoor unit 20
- Locating the outdoor unit 20
- Sac 0911 ch sac 1211 ch 20
- Wall mounted split air conditioner 20
- Illustration of the installation 21
- Indoor unit 21
- Outdoor unit 21
- Sac 0911 ch sac 1211 ch 21
- Wall mounted split air conditioner 21
- Electrical connection of the indoor unit 22
- Installing the indoor unit 22
- Installing the mounting plate 22
- Sac 0911 ch sac 1211 ch 22
- Wall mounted split air conditioner 22
- Diagram of the electrical connection of the indoor and outdoor unit 23
- Electrical connection of the outdoor unit 23
- Sac 0911 ch sac 1211 ch 23
- Wall mounted split air conditioner 23
- Disposal of used batteries 24
- Disposal of used electrical and electronic equipment 24
- Instructions and information regarding the disposal of used packaging materials 24
- Sac 0911 ch sac 1211 ch 24
- Wall mounted split air conditioner 24
Похожие устройства
- Sencor SAC 1811CH Руководство по эксплуатации
- Sencor SAC 2411CH Руководство по эксплуатации
- Номакон ПБ-101 (H52) 68-73мм 12 Вольт Инструкция по эксплуатации
- Номакон ПБ-102 (H67) 73-86мм 12 Вольт Инструкция по эксплуатации
- Номакон ПБ-103 (H52) 78-91мм 12 Вольт Инструкция по эксплуатации
- Номакон ПБ-104 (H82) 90-105мм 12 Вольт Инструкция по эксплуатации
- Номакон ПБ-105 73-86мм (I) 24 Вольта Инструкция по эксплуатации
- Номакон ПБ-106 90-105мм (I) 24 Вольта Инструкция по эксплуатации
- Номакон ПБ-107 117-125мм (I) 24 Вольта Инструкция по эксплуатации
- Номакон НТП 101 12В Инструкция по эксплуатации
- Номакон НТП 102 24В Инструкция по эксплуатации
- Dometic CDF-11 Инструкция по эксплуатации
- Dometic CDF-18 Инструкция по эксплуатации
- Dometic CDF-26 Инструкция по эксплуатации
- Dometic CDF-36 Инструкция по эксплуатации
- Dometic CDF-46 Инструкция по эксплуатации
- Dometic CF-26 Инструкция по эксплуатации
- Dometic CFX-100W Инструкция по эксплуатации
- Dometic CFX-28 Инструкция по эксплуатации
- Dometic CFX-35W Инструкция по эксплуатации
Wall Mounted Split Air Conditioner SAC 0911 CH SAC 1211 CH 7 SLEEP mode sleep 7 1 SLEEP mode Press the SLEEP button once to set the SLEEP mode 7 1 1 If the air conditioning unit is running in the cooling or drying mode the fan in the indoor unit will be set to low speed After one hour in the SLEEP mode the set temperature will increase by 1 C After another hour of operation the set temperature will again increase by 1 C The air conditioning unit will continue to run at a temperature that is 2 C higher than was set initially 7 1 2 If the air conditioning unit is running in the heating mode only on models with a heat pump the fan in the indoor unit will be set to low speed After one hour in the SLEEP mode the set temperature will decrease by 2 C After another hour of operation the set temperature will again decrease by 2 C The air conditioning unit will continue to run at a temperature that is 4 C lower than was set initially 7 2 SLEEP 1 mode Press the SLEEP button twice to set the SLEEP 1 mode 7 2 1 If the air conditioning unit is running in the cooling or drying mode and the temperature is set in the range 16 23 C then during the first three hours of the SLEEP 1 mode the temperature will increase by 1 C in each hour The air conditioning unit will then operate at a temperature that is 3 C higher than the initially set temperature After a further 8 hours of operation the temperature will decrease by 2 C The air conditioning unit will continue running at this temperature 7 2 2 If the air conditioning unit is running in the cooling or drying mode and the temperature is set in the range 24 27 C then during the first three hours of the SLEEP 1 mode the temperature will increase by 1 C in each hour The air conditioning unit will then operate at a temperature that is 2 C higher than the initially set temperature After a further 8 hours of operation the temperature will decrease by 2 C The air conditioning unit will continue running at this temperature 7 2 3 If the air conditioning unit is running in the cooling or drying mode and the temperature is set in the range 28 31 C then the air conditioning unit will continue running at the set temperature 7 2 4 If the air conditioning unit is running in the heating mode only on models with a heat pump and the temperature is set in the range 16 18 C then the air conditioning unit will continue running at the set temperature 7 2 5 If the air conditioning unit is running in the heating mode only on models with a heat pump and the temperature is set in the range 19 25 C then during the first three hours of the SLEEP 1 mode the temperature will decrease by 1 C in each hour The air conditioning unit will then operate at a temperature that is 2 C lower than the initially set temperature After a further 8 hours of operation the temperature will increase by 2 C The air conditioning unit will continue running at this temperature 7 2 6 If the air conditioning unit is running in the heating mode only on models with a heat pump and the temperature is set in the range 26 31 C then during the firstthree hours of the SLEEP 1 mode the temperature will decrease by 1 C in each hour The air conditioning unit will then operate at a temperature that is 3 C lower than the initially set temperature After a further 8 hours of operation the temperature will increase by 2 C The air conditioning unit will continue running at this temperature EN 11 Copyright 2014 Fast CR a s Revision 02 2014 Z Ш