Beko HIZG 64125 CR [13/44] Gas conversion

Содержание

Gas conversion Ck DANGER Before starting any work on the gas Installation disconnect the gas supply There is the risk of explosion In order to change your appliance s gas type change all injectors and make flame adjustment for all valves at reduced flow rate position Exchange of injector for the burners 1 Take off burner cap and burner body 2 Unscrew injectors by turning the counter clockwise 3 Fit new injectors 4 Check all connections for secure fitting and tightness _______________________ P T lNew Injectors have their position L 1 lmarkecl on their packing or injector hZ atable on Injector table page 9 can be referred to 1 2 3 4 Reduced gas flow rate setting for hob taps 1 Ignite the burner that is to be adjusted and turn the knob to the reduced position 2 Remove the knob from the gas tap 3 Use an appropriately sized screwdriver to adjust the flow rate adjustment screw For LPG Butane Propane turn the screw clockwise For the natural gas you should turn the screw counter clockwiseonce The normal length of a straight flame in the reduced position should be 6 7 mm 4 If the flame is higher than the desired position turn the screw clockwise If it is smaller turn anticlockwise 5 For the last control bring the burner both to high flame and reduced positions and check whether the flame is on or off Depending on the type of gas tap used in your appliance the adjustment screw position may Flame failure device model dependant Spark plug Injector Burner Unless there is an abnormal condition do J Jnot attempt to remove the gas burner taps ou must call an Authorised service agent if it is necessary to change the taps 1 Flow rate adjustment screw 13 EN