Tanita BC-730 White [6/52] Setting and storing personal data in memory

Tanita BC-730 White [6/52] Setting and storing personal data in memory
4
SETTING AND STORING PERSONAL DATA IN MEMORY
The unit can be operated only if data has been programmed into one of the personal data memories.
1. Turn on the Power
Press the Set button to turn on the unit.
The unit will beep to confirm activation, the Personal data number will be displayed, and the display will flash.
Note:Ifyoudon’toperatetheunitfor60secondsaftertheunithasbeenturnedon,theunitwillturnoffautomatically.
Note: If you make a mistake or want to turn the unit off before you have finished programming it, press the OFF button to force
quit.
2. Select a Personal data Number
Press the <Up/Down> buttons to select a Personal data number (1, 2, 3, 4 and 5). Once you reach the
Personal data number you wish to use, press the SET button. The unit will beep once to confirm.
3. Set your Birthday
Set the date of your birthday (Year / Month / Day) using
<Up/Down> buttons. Press the SET button to confirm at
each programming. The unit will beep once to confirm.
Note: The range of age is from 5 – 99.
4. Select Female or Male
Use the Up/Down buttons to scroll through Female ( ) or Male ( ), Female/Athlete ( / ) and
Male/Athlete (
/ ) settings, then press the Set button. The unit will beep once to confirm.
5. Specify the Height
Thedisplaydefaultsto5’70”(170cm)(rangeofheightisfrom3’0.0”–7’3.0”or90cm–220cm).
Use the <Up/Down> buttons to specify Height and then press the SET button. The unit will beep once to
confirm.Thedisplayshowsthepersonaldataonetimetoconfirm,andthenthedisplayshows“0.0”and
is ready for measurement.
6. Measuring your weight and body fat
Stepontothescaleafter“0.0”isshownondisplaywithin30seconds.
Do not step off until Body fat % in shown.
Thereadingswillbeshownfor40seconds.
The unit will then shut off and the readings will be stored in the memory.
Note:Ifyoustepontothescalebefore“0.0”appearsthedisplaywillshow“Error”andyouwillnotobtainareading.Furthermore,
ifyoudonotstepontothemeasuringscalewithinabout30secondsafter“0.0”appears,thepowerisshut-off
automatically. Please try the setting and storing personal data process again.
Note: Ifyouchangethebirthdayand/orgender,theunitwillshow“CLr”.
Ifyouselect“YES”using<Up/Down>buttons,theexistingpersonaldatawill
be deleted.
Ifyouselect“no”using<Up/Down>buttons,nonewdatawillbesaved
(existing data will be unchanged) then the unit will shut off.