OKI MC352dn [3/4] User information oki europe ltd colour printer mc352

OKI User Information OKI Europe Ltd Colour Printer MC352 It will take longer than in Ready Mode if you wish to print when the devices are in Power Save Mode This delay is known as the Recovery Time from Standby This time can be relatively long with some devices However the Oki Europe Ltd MC352 fulfills the stringent Blue Angel rquirements for Recovery Time from Standby http www blauer engel de The table shows the factory set Power Consumption values along with the Activation Time and Recovery Time from Standby values The devices are delivered with these standard settings With these standard settings the device fulfills the Blue Angel requirements General Information This printer and the corresponding consumables fulfill the Blue Angel requirements in accordance with RAL UZ 122 Energy Energy is the ability to conduct physical work For example you require energy to heat water to make the filament in a light bulb glow and print on a sheet of paper This device does not achieve zero power consumption via its on off switch If you wish to avoid electrical consumption then please disconnect the device s plug from the mains socket outlet Energy consumption can be minimised by ensuring that the product enters its lowest power mode as quickly as possible after printing has finished and disconnecting at the mains if it will be left idle for any long period of time The values also apply if the device is connected to a data network The device is designed so that its on off switch can be operated at least twice daily without any damage occurring A complete separation from the power supply can only be achieved by removing the plug from the mains Power Power means the energy used for a specific period of time Foe example the work carried out the amount of energy consumed or the amount of heat suplied for a specific period of time Kilowatt hour kWh Watt W and kilowatt kW We use different units for both energy and performance In the energy sector power is shown in Watt W or in multiple thereof for example Kilowatt kW IkW 1000W For energy the energy sector uses kilowatt hours kWh If a device with a rating of 1 kilowatt runs for one hour this will require an energy consumption of 1 kilowatt hour Conversions Overview of the Operation Modes Energy Power x Time Kilo watt hours Kilo watt x hours Energy Consumption Power consumption of the device x time during which the device consumes this power Print speed for DIN A4 format Mono 24 pages minute Colour 22 pages minute Activation Time min Recovery Time from Standby sec 480 0 Ready mode 70 143 Energy Saving mode 1 16 835 30 1 120 Mono 16 30 Colour 3 39 Energy Saving mode 2 1 084 40 1 120 Mono 36 00 Colour 23 05 Turn off 0 332 240 60 1440 Operation Mode Power Consumption watts Highest possible consumption upon turn on print 1170 0 Print Continuous Operation 5 CL 300 1 1 MC352 MC362 Power v Time Curve 1 1 250 1 200 s 150 100 50 1_____ O5 10 15 20 25 Time min 30 35 40 45 MC352 MC362 RA UZ 122 Limit Curve Power Consumption and Activation Time The amount of electricity a device consumes depends on both its properties and on the way the device is used The Oki MC352 is designed and set in a way to allow you to reduce electricity costs After the last print it switches to Ready Mode In this mode it can print again immediately if required Iffurther printing is not required the device switches to one of its power saving modes after a certain time Activation Time The device consumes less power Watt in these modes Mean values measured without accessories The Activation Time is the time that passes after the print procedure until the device switches into the mode The values in brackets indicate the range within which the Activation Time can be controlled The Recovery Time from Standby is the time that passes before the device is ready for printing again

Скачать