Stiebel Eltron PSH 150 Trend [24/92] Installation specification

Stiebel Eltron PSH 200 Trend [24/92] Installation specification
24 | PSH Trend www.stiebel-eltron.com
INSTALLATION
Specication
wall mounting bracket
30 - 50 l
184
265
300
360
80�02�07�0005
80 - 200 l
450
415
360
350
300
265
80�02�07�0006
15.2 wiring diagram
N
L
21 3 4
5
678
85�02�07�0010
1 Terminal
2 High limit safety cut-out
3 Temperature controller
4 ON/OFF indicator
5 Heating element
6 Electrical resistance 560 ohm
7 Anode
8 Cylinder
15.3 Heat-up diagrams
The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Graph assumes 15°C cold water inlet temperature:
0
1
2
3
4
5
6
35 45 55 65 75
1
2
7
6
5
4
3
D0000037214
X Temperature setting [°C]
Y Heat-up time [h]
1 150l
2 200 l
3 120l
4 100l
5 80l
6 50l
7 30l
15.4 Fault conditions
In the event of a fault, temperatures of up to 95°C at 0.6MPa
can occur.