ORAS Electra 6134 [15/52] After flow time factory set to 1 second

ORAS Electra 6134 [15/52] After flow time factory set to 1 second
After-flow Time (factory-set to 1 second)
After-flow time can be adjusted using the Oras Data Terminal (v. 2.4 or later).
Cleaning the Filter (see Figure 2)
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
Shut off the water supply to the faucet.
Unscrew the strainer (18) from the valve housing.
Clean the strainer under running water.
Screw the strainer back.
Changing the temperature regulator (see Figure 5)
Troubleshooting
Symptom Cause / Solution
Water flow from the outlet does The sensing range is too low
not stop, or stops after 2 minutes Check that the photocell is clean
The solenoid valve is damaged
Water flow is low and weak Filter is clogged
No water comes out of the faucet Check the water supply to the control box
The solenoid valve is damaged
Power failure
The photocell is covered or damaged
6105: the showerhead is not placed
properly in its wall bracket
Check the fuse (17) inside the control box:
6104 and 6105: 0.1 A
6134: 1 A