Wismec Reuleaux RX2/3, 150/200w, без аккумуляторов — устройство с высокой мощностью и множеством режимов работы [1/6]

Превью страниц Страница 1 / 6

Specification Features Size 40 2 34 5 88 7mm 2 cells 40 2 50 1 88 7mm 3 cells Thread Type 510 spring loaded thread Cell type High rate 18650 cell discharging current should be above 25A Output Mode VW TC Ni TC Ti TC SS TCR Mode Output Wattage 1 150W two cells 1 200W three cells Resistance Range 0 05 1 5ohm for TO modes 0 1 3 5ohm for VW mode Temperature Range 100 315 C 200 600 F TC modes How to use 1 Power on off Press the battery back cover lock button and the back cover will pop out automatically Then put two 18650 cells into the battery body Aiming the two notches of the back cover at the ones on the battery body press the top part and then the bottom part Press the fire button 5 times in quick succession to turn the device on and off You can do the same operation to change the back cover which can hold three cells Shift among VW TC Ni TC Ti TC SS TCR Mode 1 Press the fire button 5 times to turn the device on The OLED screen presents 4 rows of information 1 Mode VW TC Ni TC Ti TC SS TCR and Battery indicator 2 Temperature in TC modes or Output wattage in VW mode 3 Output wattage in TC modes or Voltage in VW mode 4 User information Current Puff Time and Resistance 2 Press the fire button 3 times the mode indication will flash to indicate you enter into the menu Press the right regulatory button to switch between VW TC Ni TC Ti TC SS and TCR mode Press the fire button or leave the display to flash 10 times on the current setting to confirm and exit the menu VW Mode In this mode output wattage can be adjusted from 1W to 150W 200W by pressing the regulatory buttons right to increase and left to decrease TC SS Mode The TC SS mode is suitable to SS316 coil TCR Ml M2 M3 In TCR Temperature Coefficient of Resistance mode users can set the parameters according to the TCR of coil English Note 1 The TCR value in the sheet is 105 multiplied of the actual TCR 2 The TCR value range is 1 1000 Under TCR mode when the mode indication flashing press the left regulatory button and then the sub menu items M1 M2 M3 will flash Press the right regulatory button to choose mode among M1 M2 and M3 and then press the fire button to confirm Supplementary TC Modes Functions Temperature adjustment In TC modes the temperature can be adjusted from 100 315 C or 200 600 F with the two regulatory buttons right to increase and left to decrease The Setting of TCR Mode In powered off state keep pressing the fire button and right regulatory button simultaneously then you enter into the TCR set menu 1 Press the left or right regulatory button to choose among TCR M1 M2 and M3 2 Press the fire button to confirm the mode you chosen 3 Press the left or right regulatory button to increase or decrease the parameter according to the TCR of coil 4 Keep pressing the fire button or leave the interface for about 10 seconds to confirm Shift between C and F TCR Set M1 0120 M2 0120 M3 0120 Wattage adjustment Following is the TCR value range of Reuleaux RX2 3 for your reference Material TCR Value Range Nickel 600 700 NiFe 300 400 Titanium 300 400 SS 303 304 316 317 80 200 If you increase the temperature to 315 C and continue to press the right regulatory button the temperature readings will automatically change to the lowest Fahrenheit 200 F Equally if the temperature is decreased below the minimum 100 C the unit will change back to eF automatically and the temperature will start to decrease from 600 F While the wattage sign blink press the right or left regulatory button to adjust the wattage and press fire button to confirm Long pressing the right or left regulatory button will make the wattage setting rapidly increase or decrease Resistance locked function While the resistance sign blink press the right regulatory button to lock or unlock the resistance of the atomizer Note Such operation should be carried out at room temperature English English New atomizer installation In TC mode be careful to attach new atomizers that have cooled to room temperature If a new atomizer has not cooled down before attaching the temperature may read and protect incorrectly until the new atomizer cools Note 1 When you connect a new atomizer or disconnect and reconnect your existing atomizer the device will prompt you to confirm this change and a message will prompt New Coil Right Same Coil Left Press the right regulatory button to confirm that a new atomizer has been attached Press the left regulatory button to confirm that the same atomizer has been reconnected 2 When using normal coil or the resistance of coil you used is higher than 1 5ohm in TC modes the device will automatically switch to VW mode NewCoil Q 25Q Right Same Co il 0 2QQ Left and right regulatory button to choose between logo On and Off and press the fire button to confirm You can download our logo You can also make logos to your preference and then import it through software The logo should be monochrome image in the format of bmp with limited 64 48 pixel Malfunction Indication and Protection No Atomizer Alert When the device does not detect an atomizer the OLED screen will display No Atomizer Found Atomizer Low Alert When the resistance of atomizer is lower than 0 1ohm in VW mode or lower than 0 05ohm in TC modes the OLED screen will display Atomizer Low Display of Battery Level While the battery sign flash press the right regulatory button to shift between battery symbol and battery percentage Atomizer Short circuit Protection Shift among Current Puff and Time While the user information sign blink press the right regulatory button to shift among Current Puff and Time When atomizer short circuit occurs the OLED Screen will display Atomizer Short Logo Mode Temperature Alert Reuleaux RX23 is newly added with logo mode When powered on press the fire button and right regulatory button simultaneously and then you enter into the Logo Mode By pressing the left If the internal temperature of the device is over 70 C the output will shut off automatically and the screen will display Device Too Hot Atomizer Short English 7 English will display Check USB Adapter after inserting the USB cable or vaping Over 10 Second Protection When the power button is pressed for over 10 seconds the output will shut off and the OLED screen will display Over 10s Protection Charge Error Alert When no current is detected in charging state the OLED screen will display Charge Error Temperature Protection In TC modes if the actual temperature of coil reaches the set temperature the device shows Temp Protection Check Battery Alert When one of the cells is not installed correctly the OLED screen will display Check Battery Weak Battery Alert In VW TC mode when the device installed with an atomizer is working and the voltage of battery is below 2 9V the device shows Weak Battery Meanwhile the output power will be reduced accordingly Charge I Check Error I Battery Warranty Please consult with your WISMEC distributors for warranty policy We are not responsible for any damage caused by user error This warranty is only valid for authentic WISMEC products within warranty period from date of purchase by the end user Low Power Alert If the power of battery is lower than 10 the power symbol on the screen will flash Warning 1 Keep out of reach of children 2 This product is not recommended for use by young people non smokers pregnant or breast feeding women persons who are allergic sensitive to nicotine Imbalanced Alert When the difference between the maximum and minimum cell voltage is equal or greater than 0 3V the OLED screen will display Imbalanced Batteries after inserting the USB cable Then please take out the cells to charge or replace with freshly charged cells Check USB Alert Device Too Ho Imbalanced Batteries When the voltage of the USB charger is equal or greater than 5 8V the OLED screen English Check USB Adapter Contra indication 1 Only have your product repaired by Wismec Do not attempt to repair the unit by yourself as damage or English n personal injury may occur 2 Do not leave the product in high temperature or damp conditions as this may damage the product The appropriate operation temperature is within 0 C to 45 C while charging and 10 C to 60 C while in use 3 Keep away from water Possible adverse effects 1 Use of this product may cause damage to health 2 For people with adverse reaction after using this product it is recommended to use the juice with lower nicotine content or no nicotine Manufacturer WISMEC DONGGUAN ELECTRONICS CO LTD Room 401 Building 6 of Business Accelerator No 24 Industry East Road Songshanhu High tech Industry Development Zone Dongguan Guangdong China Contact info wismec com lil P English English Op

Изучите устройство с возможностью работы в различных режимах, включая VW и TC. Подходит для высоких нагрузок и предлагает широкий диапазон настроек.