Kitano KC-Roka II-18M [49/64] Installation of refrigerant piping

Kitano KC-Roka II-18M [49/64] Installation of refrigerant piping
49
Table 7.2.2.
Model
KC-Roka
II-18M/I
KC-Roka
II-24M/I
KC-Roka
II-36M/I
KC-Roka
II-48M/I
KC-Roka
II-60M/I
Outline dimensions
A 920 920 1140 1200
B 210 270 270 300
C 570 570 710 800
D 600 600 740 830
Outlet duct
E69696980
F 712 712 933 968
G35354040
H 119 179 175 202
Inlet duct
I 812 812 1037 1096
J 210 270 270 300
K84242445
Installation
dimensions
L 958 958 1178 1237
M 427 427 541 585
N 248 427 541 585
7.3. Installation of refrigerant piping
7.3.1. Installation requirements of refrigerant piping
Because of the di erent installation positions of the air conditioners, the acces-
sory pipe for the piping is varied in length. The longer the pipe is, the more re-
frigerant is needed, therefore, please select the proper pipe as short as possible
according to the table 7.3.1.
Table 7.3.1.
Model
Maximum total piping
length, m
Maximum height di erence
between outdoor
and indoor units, m
KC-Roka II-18M 25 15
KC-Roka II-24M 30 15
KC-Roka II-36M 30 20
KC-Roka II-48M
KC-Roka II-60M
50 30