Liebherr GKPv 6570 [4/9] Warning

Liebherr GKPv 6570 [4/9] Warning
12
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the
type plate. The position of the type plate is shown in the section
entitled Description of the appliance.
Thesocketmustbeproperlyearthedandprotectedbyafuse.
The tripping current of the fuse must be between 10 A and 16 A.
Thesocketmustnotbesituatedbehindtheappli-
ance and must be easily accessible.
Donotconnecttheapplianceusinganexten-
sioncableorextensionsocket.
Donotusestand-aloneinverters(conversion
of direct current to alternating/three-phase
current)orenergy-savingplugs.Riskofdam-
agetotheelectroniccontrolsystem!
Appliance dimensions
Setting up
• Avoidpositioningtheapplianceindirectsunlightornearcookers,
radiators and similar sources of heat.
• Theflooronwhichtheappliancestandsshouldbe
horizontal and level. Compensate for uneven floors
with the adjustable feet.
To alter the height, rotate the bottom
section of the respective adjustable foot.
WARNING!
The height of the foot can be adjusted from 120 mm
to 170 mm.
Do not set the adjustable foot to a
height greater than 170 mm! The
bottom section of the adjustable
foot can become loose and the appliance may
then tip over.
This can lead to serious or even fatal injuries.
• StandardEN378specifiesthattheroominwhich youinstall
your appliance must have a volume of 1 m
3
per 8 g of R 290a
refrigerant used in the appliance, so as to avoid the formation of
inflammable gas/air mixtures in the room where the appliance is
locatedintheeventofaleakintherefrigerantcircuit.Thequantity
of refrigerant used in your appliance is indicated on the type plate
on the inside of the appliance.
• Theremustbeagapofatleast30cm
between the upper edge of the appliance
and the ceiling.
Donotcoverventilationopen-
ings or grille.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating Room temperature
4 (SN) +10°C to +32°C
4 (N) +16°C to +32°C
4+ (ST) +16°C to +38°C
4+ (SN-ST) +10°C to +38°C
5 (T) +16°C to +43°C
5 (SN-T) +10°C to +43°C
Do not operate the appliance outside the
specied room temperature range.