Castel MAC E15-40 P Инструкция по эксплуатации онлайн [13/32] 272676

Castel MAC E20-80 Инструкция по эксплуатации онлайн [13/32] 275166
GB
43
BLAST FREEZING (-18°C)
This function freezes the product completely to a temperature of -18°C in less than 4 hours.
The rapidity of the process prevents formation of macrocrystals essential to ensure that the
product retains its original consistency and quality when thawed for consumption.
AUTOMATIC CONSERVATION
At the end of each cycle (chilling or freezing), the appliance will automatically switch to the
required storage temperature.
Two different end-cycle modes are available for each cycle:
BY TEMPERATURE - the cycle ends when the probe reaches the required temperature.
TIMED - cycle length is pre-set
IMPORTANT: work cycles and modes can only be selected when the appliance is ON (LED
on push -button 6 off)
5.2 SOFT BLAST CHILLING BY TEMPERATURE (pre-cooked, hot foods)
To select this cycle, press push-button 2 (relative LED lights up), then press push-but-
ton 5 to select the temperature mode (LED 5A on)
Insert the core probe into the core of the product to be chilled.
Start up the cycle by pressing push-button 6 . LED 5A and those relative to the push-
buttons pressed illuminate throughout the cycle, while LEDs 13 flash.
Display 15 indicates the maximum blast chilling time (starting temperature to end of
the blast chilling temperature - factory setting - 90 minutes).
The temperature measured by the core probe is shown by display 16 .
The instrument timer starts the countdown of the maximum blast chilling time as soon as the
temperature measured by the core probe falls below the temperature of +65°C (the dot at
the bottom right of display 15 flashes).
During the blast chilling cycle, the air temperature is around 0°C.
This function is designed to guarantee uniform cooling of the product, preventing frost for-
mation on the surfaces. During the blast chilling cycle, the compressor may therefore stop
and restart, depending on the reading of the cell temperature probe.
The blast chilling phase ends only when the core probe (inserted in the product core) indi-
cates that the set blast chilling temperature (+3°C) has been reached as signalled by an
intermittent beep for a minute. During the beep, LEDs 13 and 14 flash.
Display 16 indicates the temperature inside the cell, while display 15 shows
blast chilling time reset to zero.