Liebherr GGPv 6590 [8/13] A01 door open e hh mm dd mm yy
![Liebherr GGPv 1470 [8/13] A01 door open e hh mm dd mm yy](/views2/1322416/page8/bg8.png)
20
Calling up the saved alarm events
>
Menu 01
Setpoint
>
Menu 06
Settings
>
Menu 05
Alarm
> The last alarm which occurred is shown in the
display.
30 alarm events are saved. The highest gure (A _ _) is the last
alarm which occurred. Select a previous alarm event by pressing
the buttons
and .
>
A01 Door Open
S hh:mm DD/MM/YY
Start of the alarm event with time and date.
>
A01 Door Open
E hh:mm DD/MM/YY
End of the alarm event with time and date.
>
A01 Door Open
Temp Max - - °C
Highest temperature reached inside the appliance.
Return to the standard indication by pressing the
button.
Note
After this query, the alarm display will be deleted automatically.
Menu 05
Alarm
= list of alarms
The alarm events are saved and can be called up if required.
The following alarm can be rectied immediately:
Door Open
Temp. - - °C
When the door is open, the above indication and the standard
indication ash alternately. After 240 seconds, the audible warn-
ing signal sounds.
Cancel the audible warning signal by pressing button
. Close
the appliance door.
The following alarm events require the stored items
to be checked:
1.
ALL Power cut
Temp. - - °C
The above indication and the standard indication ash alternately.
This indication is displayed after a power failure.
Press button
to delete this display.
Call up the length of the power failure and the maximum tempera-
ture reached inside the appliance. See chapter "Calling up the
saved alarm events".
2.
High Temp Room
Temp. - - °C
The above indication and the standard indication ash alternately.
The audible warning signal sounds.
Cancel the audible warning signal by pressing button
.
This can be caused by:
• the appliance door being left open for a long time, allowing warm
ambient air to enter;
• a long power failure;
• a fault in the appliance.
If a large quantity of warm items is placed in the appliance at once,
this alarm may occur. This does not mean that there is an error.
Call up the length of the temperature rise and the maximum tem-
perature reached inside the appliance. See chapter "Calling up
the saved alarm events".
In both cases, the items must be checked and it must be
decided if they can still be used.
A l l o t h e r a l a r m s w h i c h o c c u r m u s t b e r e c t i e d b y a c u s t o m e r
service technician.
Alarm test
To check that the alarm function is working correctly, an alarm
test should be carried out at regular intervals.
5 seconds
>
Alarm Test
The display ashes and the audible warning signal sounds. The
alarm test is terminated automatically after a few seconds.
Содержание
- 263 01 1
- Operating instructions 1
- Content 2
- Description of the appliance 2
- Ggpv 1490 ggpv 6590 2
- Stacking mark 2
- Appliance dimensions 4
- Climate rating 4
- Do not cover ventilation open ings or grille 4
- Do not operate the appliance outside the specified room temperature range 4
- Do not set the adjustable foot to a height greater than 170 mm the bottom section of the adjustable foot can become loose and the ap pliance may then tip over 4
- Electrical connection 4
- Range of appliance use 4
- Setting up 4
- The appliance is suited only for cooling food 4
- The height of the foot can be adjusted from 120 mm to 170 mm 4
- The socket must not be situated behind the appli ance and must be easily accessible 4
- This can lead to serious or even fatal injuries 4
- Warning 4
- Equipment 5
- Button 6
- Dd mm yy hh mm ss 6
- Frozen food temp c 6
- Keypad lock 6
- Language english 6
- Menu 01 setpoint 6
- Menu 06 settings 6
- Operating and control elements 6
- Setting the language 6
- Settings 01 service 6
- Settings 02 language 6
- Switching the appliance on and off 6
- Main menu 7
- Menu 01 7
- Menu 01 setpoin 7
- Menu 01 setpoint 7
- Menu 03 7
- Menu 03 defrostin 7
- Menu 03 defrosting 7
- Menu 04 7
- Menu 04 program 7
- Menu 04 programs 7
- Menu 05 7
- Menu 05 alarm 7
- Menu 06 7
- Menu 06 settings 7
- New set c current c 7
- P12 frozen food 7
- P12 set 20 c frozen food 7
- P13 ice cream 7
- P14 ice cream scoop 7
- Start defrosting no ok 7
- A01 door open e hh mm dd mm yy 8
- A01 door open s hh mm dd mm yy 8
- A01 door open temp max c 8
- Alarm test 8
- All power cut temp c 8
- Calling up the saved alarm events 8
- Door open temp c 8
- High temp room temp c 8
- Menu 01 setpoint 8
- Menu 05 alar 8
- Menu 05 alarm 8
- Menu 06 settings 8
- The following alarm can be rectified immediately 8
- The following alarm events require the stored items to be checked 8
- D03 0 0 9
- D03 0 1 9
- D03 0 backlight on 9
- Date dd mm yy hour hh mm ss 9
- External alarm 9
- Menu 01 setpoint 9
- Menu 06 setting 9
- Menu 06 settings 9
- Settings 01 service 9
- Settings 02 language 9
- Settings 03 clock setting 9
- Settings 06 display 9
- The appliance may only be connected to an ex ternal alarm device by trained personnel 9
- A12 45 c 45 c 10
- A12 45 c p low alarm 10
- A13 45 c 45 c 10
- A13 45 c p high alarm 10
- Adjusting the alarm limits 10
- Frozen food product c 10
- Menu 01 setpoint 10
- Menu 06 settings 10
- Product sensor 10
- Product sensor settings 10
- Remove the plug 10
- Sensor check off 10
- Sensor check on 10
- Settings 01 service 10
- Settings 09 alarm setting 10
- A14 0 min 0 min 11
- A14 0 min p alarm delay 11
- Cleaning 11
- Dd mm yy hh mm ss 11
- Do not use steam cleaners because of the risk of injury and damage 11
- Frozen food product c 11
- Frozen food temp c 11
- Malfunctions 11
- Shutting your appliance down 11
- Temp c product c 11
- Changing over door hinges ggpv 6590 12
- If the door is removed and reinstalled in the closed position this will lead to destruction of the self closing mechanism on the first open ing of the door 12
- Warning 12
- Warning 13
Похожие устройства
- Liebherr GKPv 1470 Инструкция по эксплуатации
- Liebherr GGv 5860 Инструкция по эксплуатации
- Liebherr LGT 2325 Инструкция по эксплуатации
- Liebherr LGT 2325 Каталог оборудования Liebherr (англ.)
- Liebherr LGT 4725 Инструкция по эксплуатации
- Liebherr LGT 4725 Каталог оборудования Liebherr (англ.)
- Liebherr LGT 3725 Инструкция по эксплуатации
- Liebherr LGT 3725 Каталог оборудования Liebherr (англ.)
- TEFCOLD FR605/R600 Инструкция по эксплуатации
- TEFCOLD SE20-45 Инструкция по эксплуатации
- TEFCOLD BA25H-I Инструкция по эксплуатации
- Scan SD 76 Инструкция по эксплуатации
- Scan SD 76 Схема
- TEFCOLD SC85-I Инструкция по эксплуатации
- CAS NC-100 Инструкция по эксплуатации
- CAS Caston-I 1 THA Инструкция по эксплуатации
- CAS Caston-I 3 THA Инструкция по эксплуатации
- CAS Caston-I 5 THA Инструкция по эксплуатации
- CAS NC-200 Инструкция по эксплуатации
- CAS Caston-III 1 THD Инструкция по эксплуатации