Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE [3/28] Afety precautions
![Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE [3/28] Afety precautions](/views2/1324287/page3/bg3.png)
En-2
Your MITSUBISHI ELECTRIC product is designed and manufactured with high
quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and
accumulators, at their end-of-life, should be disposed of separately from your
household waste.
If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical sym-
bol means that the battery or accumulator contains a heavy metal at a certain
concentration. This will be indicated as follows:
Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)
In the European Union there are separate collection systems for used electrical
and electronic products, batteries and accumulators.
Please, dispose of this equipment, batteries and accumulators correctly at your
local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
Note:
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2002/96/
EC Article 10 Information for users and Annex IV, and/
or to the directive 2006/66/EC Article 20 Information for
end-users and Annex II.
CAUTION
Do not touch the air inlet or the aluminum fi ns of the indoor/
outdoor unit.
• This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
• This may cause a re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
• This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the
indoor/outdoor unit.
• Water may drip down from the unit, which may cause damage or
malfunction.
Do not leave the unit on a damaged installation stand.
• The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the unit.
• This may cause injury if you fall down.
Do not pull the power cord.
• This may cause a portion of the core wire to break, which may
cause overheating or re.
Do not charge or disassemble the batteries, and do not throw
them into a fi re.
•
This may cause the batteries to leak, or cause a re or explosion.
Do not operate the unit for more than 4 hours at high humidity (80%
RH or more) and/or with windows or outside door left open.
• This may cause the water condensation in the air conditioner, which
may drip down, wetting or damaging the furniture.
• The water condensation in the air conditioner may contribute to
growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing food,
raising animals, growing plants, or preserving precision devices
or art objects.
• This may cause deterioration of quality, or harm to animals and
plants.
Do not expose combustion appliances to direct airfl ow.
• This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid ac-
cidental ingestion.
• Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the power
plug or turn the breaker OFF.
• This may cause injury, since the fan inside rotates at high speeds
during operation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
• The unit may accumulate dirt, which may cause overheating or
re.
Replace all batteries of the remote controller with new ones of
the same type.
• Using an old battery together with a new one may cause overheat-
ing, leakage, or explosion.
If the battery fl uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
•
If the battery uid comes in contact with your eyes, wash them thor-
oughly with clean water and immediately seek medical attention.
Ensure that the area is well-ventilated when the unit is operated
together with a combustion appliance.
• Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a pos-
sibility of a lightning strike.
• The unit may be damaged if lightning strikes.
To dispose of this product, consult your dealer.
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air con-
ditioner may cause water leakage, re, or electric shock.
Provide a dedicated power supply for the air conditioner.
• A non-dedicated power supply may cause overheating or re.
Do not install the unit where fl ammable gas could leak.
• If gas leaks and accumulates around the outdoor unit, it may cause
an explosion.
Earth the unit correctly.
• Do not connect the earth wire to a gas pipe, water pipe, lightning
rod, or a telephone ground wire. Improper earthing may cause
electric shock.
CAUTION
Install an earth leakage breaker depending on the installation
location of the air conditioner (such as highly humid areas).
• If an earth leakage breaker is not installed, it may cause electric
shock.
Ensure that the drain water is properly drained.
• If the drain passage is improper, water may drip down from the
indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
SAFETY PRECAUTIONS
After the air conditioner is used for several seasons, perform
inspection and maintenance in addition to normal cleaning.
• Dirt or dust in the unit may create an unpleasant odor, contribute
to growth of fungi, such as mold, or clog the drain passage, and
cause water to leak from the indoor unit. Consult your dealer for
inspection and maintenance, which require specialized knowledge
and skills.
Do not operate switches with wet hands.
• This may cause electric shock.
Do not clean the air conditioner with water or place an object that
contains water, such as a fl ower vase, on it.
• This may cause re or electric shock.
Do not step on or place any object on the outdoor unit.
• This may cause injury if you or the object falls down.
DISPOSAL
For installation
Fig. 1
IMPORTANT
Dirty fi lters cause condensation in the air conditioner which will contribute
to the growth of fungi such as mold. It is therefore recommended to clean air
fi lters every 2 weeks.
Before starting the operation, ensure that the horizontal vanes are in the closed
position. If operation starts when the horizontal vanes are in the open position,
they may not return to the correct position.
SG79F661H03.indb 2 2013-12-25 1:41:40
Содержание
- Deutsch 1
- English 1
- Español 1
- Français 1
- Indoor unit 1
- Italiano 1
- Msz fh25ve msz fh35ve msz fh50ve 1
- Nederlands 1
- Português 1
- Split type air conditioners 1
- Svenska 1
- Türkçe 1
- Ελληνικά 1
- Русский 1
- Afety precautions 2
- Ontents 2
- Warning 2
- Afety precautions 3
- Caution 3
- For installation 3
- Important 3
- Isposal 3
- Warning 3
- Ame of each part 4
- Indoor unit remote controller 4
- Installing the remote controller batteries setting current time 4
- Operating instructions 4
- Outdoor unit 4
- Remote controller holder 4
- Reparation before operation 4
- Reparation before operation 5
- Setting the installation position 5
- Absence detection 6
- I see control mode 6
- Indirect direct mode 6
- See operation 6
- Auto mode auto change over 7
- Cool mode 7
- Dry mode 7
- Electing operation modes 7
- Fan mode 7
- Heat mode 7
- Operation indicator lamp 7
- Airflow direction 8
- An speed and airflow direction adjustment 8
- Cono cool operation 9
- I save operation 9
- Press again to cancel econo cool operation 9
- Press again to cancel i save operation 9
- Press during cool econo cool or heat mode to select i save mode 9
- Press during cool mode page 6 to start econo cool operation 9
- Save operation 9
- Set the temperature fan speed and airfl ow direction 9
- What is econo cool 9
- Atural flow operation 10
- Imer operation on off timer 10
- Ir purifying operation 10
- Owerful operation 10
- Checking weekly timer setting 11
- Eekly timer operation 11
- Setting the weekly timer 11
- Air cleaning fi lter electrostatic anti allergy enzyme fi lter blue 12
- Air purifying device 12
- Air fi lter 12
- Deodorizing fi lter black 12
- Front panel 12
- Instructions 12
- Leaning 12
- Airfl ow 13
- Does not cool or heat 13
- Even if these items are checked when the unit does not recover from the trouble stop using the air conditioner and consult your dealer 13
- Hen you think that trouble has occurred 13
- In the following cases stop using the air conditioner and consult your dealer when water leaks or drips from the indoor unit when the operation indicator lamp blinks when the breaker trips frequently the remote control signal is not received in a room where an electronic on off type fl uorescent lamp inverter type fl uorescent lamp etc is used operation of the air conditioner interferes with radio or tv reception an ampli fi er may be required for the affected device when an abnormal sound is heard 13
- Indoor unit 13
- Multi system 13
- Outdoor unit 13
- Remote controller 13
- Symptom explanation check points 13
- Electrical work 14
- Installation place 14
- Nstallation place and electrical work 14
- Pecifications 14
- When using the air conditioner again 14
- Еры предосторожности 15
- Неправильное обращение с прибором представляет собой серьезную угрозу в зависимости от конкретных обстоятельств 15
- Неправильное обращение с прибором представляет собой серьезную угрозу для здоровья или с большой степенью вероятности может при вести к смертельному исходу или получению тяжелой травмы и т д 15
- Обязательно отсоедините вилку шнура питания от розетки электропитания 15
- Одержание 15
- После прочтения храните данное руководство вместе с руководством по установке прибора в легкодоступном месте и пользуйтесь ими для справок 15
- Предупреждение 15
- Так как предостерегающая информация содержащаяся в данном разделе каса ется вашей безопасности обязательно следуйте изложенным инструкциям 15
- Важно 16
- Еры предосторожности 16
- Осторожно 16
- Предупреждение 16
- При установке прибора 16
- Тилизация 16
- Азвания отдельных частей прибора 17
- Внутренний прибор пульт дистанционного управления 17
- Инструкции по эксплуатации 17
- Наружный прибор 17
- Одготовка прибора к эксплуатации 17
- Установка батареек пульта дистанци онного управления установка текущего времени 17
- Настройка места установки 18
- Одготовка прибора к эксплуатации 18
- Примечание 18
- Перация i see 19
- Режим indirect direct непрямой прямой 19
- Режим управления i see 19
- Автоматический режим auto автоматическое переключение 20
- Индикаторная лампочка работы 20
- Работа мультисистемной модели 20
- Режим вентиляции fan 20
- Режим обогрева heat 20
- Режим охлаждения cool 20
- Режим сушки dry 20
- Ыбор режимов работы 20
- Астройка скорости вентилятора и направления воздушного потока 21
- Направление потока воздуха 21
- Примечание 21
- В режиме cool нажмите cтр 6 чтобы запустить функцию econo cool 22
- Для выбора режима i save нажмите во время работы кондиционера в режимах cool econo cool или heat 22
- Для отмены операции i save снова нажмите 22
- Задайте температуру скорость вентилятора и на правление воздушного потока 22
- Операция i save 22
- Перация i save 22
- Ункция econo cool 22
- Что такое функция econo cool 22
- Де ние или fan вентилятор стр 6 чтобы запустить режим natural flow естественный поток 23
- Ежим powerful 23
- Ежим естественного потока 23
- Ежим таймера таймер on off nos 23
- Таймер включения в заданное время прибор включится 23
- Таймер выключения в заданное время прибор выключится 23
- Что такое natural flow естественный поток 23
- Что такое режим air purifying очистка воздуха 23
- Настройка недельного таймера 24
- Проверка настройки недельного таймера 24
- Спользование недельного таймера 24
- Воздушный фильтр 25
- Дезодорирующий фильтр черный 25
- Истка 25
- Передняя панель 25
- Устройство очистки воздуха 25
- Фильтр очистки воздуха электростатический антиаллергенный энзимный фильтр синий 25
- В следующих случаях необходимо остановить работу кондиционера и обратиться к своему дилеру если из внутреннего прибора просачивается вода если мигает индикаторная лампочка работы если часто срабатывает прерыватель тока в сети сигнал с пульта дистанционного управления не принимается в помещении где установлены люминесцентные лампы включение выключение которых производится с помощью электронного устройства люминесцен тные лампы инверторного типа и т д при работе кондиционера воздуха возникают помехи при приеме радио или телевещания для нормального приема теле и радиовещания может потребоваться усилитель при поступлении необычного звука 26
- Внутренний прибор 26
- Звук 26
- Мультисистемная модель 26
- Наружный прибор 26
- Не охлаждает и не греет 26
- Поток воздуха 26
- Пульт дистанционного управления 26
- Симптом объяснение и точки проверки 26
- Сли вам кажется что прибор неисправен 26
- Таймер 26
- Ехнические характеристики 27
- Head office tokyo bldg 2 7 3 marunouchi chiyoda ku tokyo 100 8310 japan 28
- Sg79f661h03 28
Похожие устройства
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Брошюра
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Руководство по установке
- Mitsubishi Electric MJ-E16PX Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Брошюра
- GE Monogram ZISP 480 DX SS Инструкция по эксплуатации
- GE Monogram ZISP 480 DX SS Брошюра
- Mitsubishi Electric SEZ-KD25VAQ / SUZ-KA25VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD25VAQ / SUZ-KA25VA Брошюра
- Mitsubishi Electric SEZ-KD25VAQ / SUZ-KA25VA Руководство по установке
- Mitsubishi Electric MFZ-KA25VA / SUZ-KA25VA Инструкция по эксплуатации
- Mitsubishi Electric MFZ-KA25VA / SUZ-KA25VA Брошюра
- Mitsubishi Electric MFZ-KA25VA / SUZ-KA25VA Руководство по установке
- GE Monogram ZISS 420 NX SS Инструкция по эксплуатации
- GE Monogram ZISS 420 NX SS Брошюра
- Mitsubishi Electric SEZ-KD60VAQ / SUZ-KA60VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD60VAQ / SUZ-KA60VA Брошюра
- Mitsubishi Electric SEZ-KD60VAQ / SUZ-KA60VA Руководство по установке
- Mitsubishi Electric SEZ-KD71VAQ / SUZ-KA71VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD71VAQ / SUZ-KA71VA Брошюра