Liebherr BCDv 4313 [3/5] Connecting to the mains

Liebherr BCDv 4313 [3/5] Connecting to the mains
7
Lighting for BCD4302 and BCDv4312
Theinternallightconsistsofuorescenttubeandlocatedonthe
inner cabinet right side in BCDv4312 while BCDv4302 internal light
is located on the inner cabinet top side.
The lighting of the display on top of the unit is also illuminated by
uorescenttube.
Lighting for BCDv4313
ThelightingforinterioranddisplayinthismodelisbyLED.
The interior light together with the dis-•
playlightcanbeturnedonandousing
the switch S.
The lighting can only be replaced by Customer Service or
by trained professionals! Do not try to change the lighting
on your own.
Caution - class 1M laser radiation. When cover is removed,
do not look directly at light through optical instruments.
Safety lock
Thelockisequippedwithasafetymechanism.
Locking the appliance:
• Insertthekeyasshownbyarrow1.
• Turnthekey90°.
Tounlocktheappliance,thesameproceduremustberepeatedin
the same order.
Setting the temperature
Using a coin, turn the arrow of the temperature
control T to a setting between 1 and 7.
Setting 1 = highest temperature
Setting 7 = lowest temperature
Temperature Display
The thermometer is located on the left of inner compartment
GB
Setting up
•Avoidpositioningtheapplianceindirectsunlight
ornearcookers,radiatorsandsimilarsourcesof
heat.
•Theooronwhichtheappliancestandsshould
be horizontal and level. Compensate for uneven
oorswiththeadjustablefeet.
•Theremustbeagapofatleast30cmbetweentheupperedge
of the appliance and the ceiling. Always ensure that there is
goodventilationandthattheoutwardowingairisabletoes-
cape.
• StandardEN378speciesthattheroominwhichyouinstall
your appliance must have a volume of 1 m
3
per8gofR600a
(R290)refrigerantusedintheappliance,soastoavoidthe
formationofinammablegas/airmixturesintheroomwhere
theapplianceislocatedintheeventofaleakintherefrigerant
circuit.Thequantityofrefrigerantusedinyourapplianceisindi-
cated on the type plate on the inside of the appliance.
•Alwaysinstalltheappliancedirectlyagainstthewall.
Connecting to the mains
Powersupply(AC)andvoltageattheoperatingpointmustcomply
withthedetailsonthetypeplate.Thesocketmustbefusedwitha
10A fuse or higher, it must be away from the rear of the appliance
and must be easily accessible.
Connect the appliance with a properly earthed fused plug
and socket only.
Cooling
This appliance can be used for chilling all types of drinks and
food.
The grid shelves can be moved to
accommodatedierentheightbot-
tlesorpackages.
High-percentage alcohols should be
tightly sealed and stored upright.
The ventilation slots on the inside
must not be covered!
Switching the appliance on and o
Youarerecommendedtocleantheappliance
beforeswitchingit on forthersttime(see
Cleaning).
To switch the appliance on: Connect the
appliance to the mains - the appliance is
switched on.
To switch the appliance o: Pull out the
mains plug or set the temperature control
to T “•”.
c