Mitsubishi Electric PLFY-P100VBM-E [7/24] Operation
![Mitsubishi Electric PLFY-P32VBM-E [7/24] Operation](/views2/1331639/page7/bg7.png)
7
GB
3. Operation
<Exiting the Main menu screen>
Press the [RETURN] button to exit
the Main menu and return to the
Main display.
F1 F2 F3 F4
Cool
Room
AutoSet temp.
Mode Temp. Fan
Fri
If no buttons are touched for 10 minutes, the screen will automatically
return to the Main display. Any settings that have not been saved will
be lost.
<Display of unsupported functions>
The message at left will appear if
the user selects a function not sup-
ported by the corresponding indoor
unit model.
F1 F2 F3 F4
Title
Not available
Unsupported function
Return:
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 6), and press the [SELECT]
button.
<Vane setting>
F1 F2 F3 F4
Fri
Swing Off Off
LouverVent.Vane
Cool
Room
AutoSet temp.
Mode Temp. Fan
Fri
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Swing
Step 1 Step 2
Step 4Step 3
Swing
Step 5
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
WKHYDQHZLOOEH¿[HGDWWKHVH-
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 5" and the
fan operates at low speed during
cooling or dry operation (depends
on the model).
The icon will go off in an hour,
and the vane setting will auto-
matically change.
<Vent. setting>
F1 F2 F3 F4
Fri
Low
Vent.
<Returning to the Main menu>
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Note:
Ɣ
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Ɣ Available directions depend on the type of unit connected.
Ɣ
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
+RZWRVHWWKH¿[HGXSGRZQDLUGLUHFWLRQ2QO\IRU
wired remote controller) >
Note:
Ɣ This function cannot be set depending on the outdoor unit to be
connected.
)RU3/)<9%0VHULHVRQO\WKHSDUWLFXODURXWOHWFDQEH¿[HGWRFHUWDLQ
GLUHFWLRQZLWKWKHSURFHGXUHVEHORZ2QFH¿[HGRQO\WKHVHWRXWOHW
LV¿[HGHYHU\WLPHDLUFRQGLWLRQHULVWXUQHGRQ2WKHURXWOHWVIROORZ
UP/DOWN air direction setting of remote controller.)
Ŷ
Manual vane angle
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Maintenance
Initial setting
Service
F1 F2 F3 F4
Maintenance menu
Main menu:
Cursor
Auto descending panel
Manual vane angle
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off Low High
Off Low High
7KHIDQRQVRPHPRGHOVRILQGRRU
units may be interlocked with cer-
tain models of ventilation units.
Press the [RETURN] button to go
back to the Main menu.
1 Select "Maintenance" from the
Main menu (refer to page 6), and
press the [SELECT] button.
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT] button.
Содержание
- Air conditioners for building application indoor unit 1
- Bedieningshandleiding 1
- Bedienungshandbuch 1
- Deutsch d 1
- English gb 1
- Español e 1
- Français f 1
- Istruzioni di funzionamento 1
- Italiano i 1
- Manual de instrucciones 1
- Manual de operação 1
- Manuel d utilisation 1
- Nederlands nl 1
- Operation manual 1
- Plfy p vbm e 1
- Português p 1
- Contents 2
- Disposing of the unit 2
- Safety precautions 2
- Symbols used in the illustrations 2
- Symbols used in the text 2
- Controller interface 3
- Parts names 3
- Auto set temp 4
- Cool auto set temp 4
- Display 4
- Mode temp fan 4
- Parts names 4
- Mode selection 5
- Operation 5
- Temperature setting 5
- Turning on off on off 5
- Airflow direction setting 6
- Fan speed setting 6
- Operation 6
- Operation 7
- Operation 8
- Ventilation 8
- Care and cleaning 9
- Troubleshooting 10
- Specifications 11
- Troubleshooting 11
- Auto set temp 14
- Cool auto set temp 14
- Mode temp fan 14
- F1 f2 f3 f4 16
- Mon tue wed thu fri sat sun start stop silent 16
- Ou silent mode 16
- Setting display 16
- Attenzione 23
- Caution 23
- Cuidado 23
- English is original the other languages versions are translation of the original 23
- Försiktighet 23
- Ginalet 23
- Il testo originale è redatto in lingua inglese le altre versioni linguistiche rappre sentano traduzioni dell originale 23
- L anglais est l original les versions fournies dans d autres langues sont des tra ductions de l original 23
- Ma original 23
- Precaution 23
- Son traducciones del original 23
- Voorzichtig 23
- Vorsicht 23
Похожие устройства
- Mitsubishi Electric PLFY-P100VBM-E Инструкция по установке
- Mitsubishi Electric PLFY-P100VBM-E Сертификат
- Mitsubishi Electric PLFY-P20VCM-E Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P20VCM-E Инструкция по установке
- Mitsubishi Electric PLFY-P20VCM-E Сертификат
- Mitsubishi Electric PLFY-P32VBM-E Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P32VBM-E Инструкция по установке
- Mitsubishi Electric PLFY-P32VBM-E Сертификат
- Mitsubishi Electric PLFY-P32VLMD Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P32VLMD Сертификат
- Mitsubishi Electric PLFY-P40VCM-E Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P40VCM-E Инструкция по установке
- Mitsubishi Electric PLFY-P40VCM-E Сертификат
- Mitsubishi Electric PLFY-P80VBM-E Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P80VBM-E Инструкция по установке
- Mitsubishi Electric PLFY-P80VBM-E Сертификат
- Mitsubishi Electric PLFY-P25VCM-E Инструкция по эксплуатации
- Mitsubishi Electric PLFY-P25VCM-E Инструкция по установке
- Mitsubishi Electric PLFY-P25VCM-E Сертификат
- Mitsubishi Electric PLFY-P40VBM-E Инструкция по эксплуатации