[Shield wire connection]
[Fig. 7.3.4] (P.4)
A Terminal block B Round terminal
C Shield wire
D The earth wire from two cables are connected together to the S terminal. (Dead-
end connection)
E Insulation tape (To keep the earth wire of the shielded cable from coming in con-
tact with the transmission terminal)
5. After wiring is complete, make sure again that there is no slack on the connec-
tions, and attach the cover onto the terminal block box in the reverse order of
removal.
Notes:
• Do not pinch the cables or wires when attaching the terminal block box
cover. Doing so may cause a risk of disconnection.
• When accommodating the terminal block box, make sure that the con-
nectors on the box side are not removed. If removed, it cannot operate
normally.
Caution:
Fix the electrical wires at site using clamps.
Caution:
Wire the power supply so that no tension is imparted. Otherwise disconnec-
tion, heating or fire may result.
7.4. Selecting the external static pressure
As the factory setting is for use under an external static pressure of 20 Pa, no
switch operation is needed when using under the standard condition.
[Fig. 7.4.1] (P.4)
<Address board>
7.5. Setting addresses
(Be sure to operate with the main power turned OFF.)
[Fig. 7.4.1] (P.4)
<Address board>
• There are two types of rotary switch setting available: setting addresses 1 to 9
and over 10, and setting branch numbers.
1 How to set addresses
Example: If Address is “3”, remain SW12 (for over 10) at “0”, and match
SW11(for 1 to 9) with “3”.
2 How to set branch numbers SW14 (Series R2 only)
The branch number assigned to each indoor unit is the port number of the
BC controller to which the indoor unit is connected.
Leave it to “0” on the non-R2 series of units.
• The rotary switches are all set to “0” when shipped from the factory. These
switches can be used to set unit addresses and branch numbers at will.
• The determination of indoor unit addresses varies with the system at site. Set
them referring to the Data Book.
7.6. Sensing room temperature with the
built-in sensor in a remote controller
If you want to sense room temperature with the built-in sensor in a remote control-
ler, set SW1-1 on the control board to “ON”. The setting of SW1-7 and SW1-8 as
necessary also makes it possible to adjust the air flow at a time when the heating
thermometer is OFF.
External static pressure Switch operation
20 Pa
40 Pa
60 Pa
SWC
3
2
1
SWA
SWC
3
2
1
SWA
SWC
3
2
1
SWA
2
1
2
1
2
1
WT05228X01_en 07.8.24, 6:05 PM10
Содержание
- Air conditioners for building application indoor unit 1
- E xeipi io o h iøn e kata ta h 1
- Installatiehandleiding 1
- Installation manual 1
- Installationshandbuch 1
- Manual de instalación 1
- Manual de instalação 1
- Manuale di installazione 1
- Manuel d installation 1
- Montaj elk tabi 1
- Pffy p vlrmm e 1
- Руководство по установке 1
- I i k j 4
- M2 s m1 4
- Before installation and electric work 5
- Caution 5
- Contents 5
- Gb d f i nl e p gr ru tr 5
- Precautions for devices that use r410a refrigerant 5
- Safety precautions 5
- Symbols used in the illustrations 5
- Symbols used in the text 5
- Warning 5
- Before getting installed 6
- Before getting installed moved elec trical work 6
- Before starting the test run 6
- Caution 6
- Gb d f i nl e p gr ru tr 6
- Indoor unit accessories 6
- Selecting an installation site 6
- Warning 6
- Assembling the unit 7
- Center of gravity and product weight 7
- Combining indoor units with outdoor units 7
- Gb d f i nl e p gr ru tr 7
- Installing the unit 7
- Refrigerant pipe and drain pipe size 7
- Refrigerant pipe and drain pipe specifications 7
- Securing installation and service space 7
- Caution 8
- Cautions on refrigerant piping 8
- Connecting refrigerant pipes and drain pipes 8
- Drain piping work 8
- Electrical wiring 8
- Gb d f i nl e p gr ru tr 8
- Precautions on electrical wiring 8
- Refrigerant piping work 8
- Types of control cables 8
- Warning 8
- Caution 9
- Connecting electrical wires 9
- Connecting remote controller indoor and outdoor transmission cables 9
- Gb d f i nl e p gr ru tr 9
- Power supply wiring 9
- Caution 10
- Gb d f i nl e p gr ru tr 10
- Selecting the external static pressure 10
- Sensing room temperature with the built in sensor in a remote controller 10
- Setting addresses 10
Похожие устройства
- Mitsubishi Electric PFFY-P25VLRMM-E Сертификат
- Mitsubishi Electric PFFY-P50VLRM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P50VLRM-E Инструкция по установке
- Mitsubishi Electric PFFY-P50VLRM-E Сертификат
- Mitsubishi Electric PFFY-P25VLRM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P25VLRM-E Инструкция по установке
- Mitsubishi Electric PFFY-P25VLRM-E Сертификат
- Mitsubishi Electric PFFY-P63VLRM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P63VLRM-E Инструкция по установке
- Mitsubishi Electric PFFY-P63VLRM-E Сертификат
- Mitsubishi Electric PFFY-P40VLRM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P40VLRM-E Инструкция по установке
- Mitsubishi Electric PFFY-P40VLRM-E Сертификат
- Mitsubishi Electric PFFY-P50VLRMM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P50VLRMM-E Инструкция по установке
- Mitsubishi Electric PFFY-P50VLRMM-E Сертификат
- Mitsubishi Electric PFFY-P32VLRMM-E Инструкция по эксплуатации
- Mitsubishi Electric PFFY-P32VLRMM-E Инструкция по установке
- Mitsubishi Electric PFFY-P32VLRMM-E Сертификат
- Mitsubishi Electric PEFY-P40VMS1-E Инструкция по эксплуатации