AFLV _FL06_IT-EN Rev.01 11-2014 pag. 50
6.7 - ALARMS
Opening the door stops ventilation and steam injection. If prolonged, a buzzer sounds.
Faults and operational anomalies are shown by the alarms described below, which appear on display (A) and are signalled
by a buzz:
- AL1: cabinet probe error. All regulations are blocked. This is a fault that requires checking of the PTC probe in
the cabinet, and its replacement. Resetting is manual by means of the start button (G).
- AL2: safety thermostat alarm (if applicable). Signals over-temperature inside the cabinet and coincides with the
cutting in of the safety thermostat, which turns off the power to the heating elements until the thermostat is
automatically reset. The cycle must be re-started manually by pressing Start (G).
- AL3: defrosting probe error. All regulations are blocked. This is a fault that requires checking of the PTC probe
on the evaporator, and its replacement.
- AL6: possible error in clock data. Any cycle in progress is stopped. The clock does not necessarily work
properly during times when the circuit board is not powered. Resetting is manual by pressing and holding down
button (H) for 5 seconds.