WANDA - WANDA CLASSIC
7097030 21
Room heating takes place:
a) By irradiation: through the panoramic glass and the external hot surfaces of the stove, the heat is radiated into the environment;
b) By natural convection: the passage of air through the coating and the covering hood releases heat in the room.
c) By forced convection: a ventilation kit suitable to improve the distribution of heat by ventilation only either of the installation room
or of the adjacent local.
ACCESSORIES
POKER GLOVE
WANDA SERIES SERIES
WANDA CLASSIC SERIES SERIES
The device is equipped with registers of primary and secondary air.
A- PRIMARY air register
With the primary air control (Picture 7 at page 70 - A) is adjusted the passage of air through the ash drawer and the grate in the fuel
direction. The primary air is necessary for the combustion process. The ash drawer must be regularly emptied, so that the ash does not
obstruct the primary air entry. Through the primary air the re is also kept alive.
During wood combustion, the register of primary air must be opened only for a while, because otherwise the wood burns fast and the
stove may overheat. For the correct arrangement (see chapter Normal operation).
B - SECONDARY air register
Over the door of the hearth there is the secondary air control (Picture 7 at page 70 - B).This regulator must be open (the lever must be
moved to the right), especially for wood combustion, so that un-burnt carbon does not undergo a post-combustion. See chapter Normal
operation. Through this register it is possible to adjust the power of the stove.
Leaving it slightly open, according to the ue of the chimney, it is possible to keep the glass clean.
The adjustment of the registers necessary to reach the rated caloric yield is the following one:
Hourly consumption in Kg/h PRIMARY air SECONDARY air TERTIARY AIR
WANDA 2,8 CLOSED 1/2 OPEN PRE - ADJUSTED
WANDA CLASSIC 2,8 CLOSED 1/2 OPEN PRE - ADJUSTED
C - AIR REGISTER for the heating of the environment (Picture 7 at page 70 pos. C).
This register, through a fan controlled by a thermoregulator pos. D, adjusts the warm air output ONLY from the front side of the appliance.
D - FAN ELECTRIC THERMOCONTROLLER (Picture 7 at page
pos. D).
UNIT OPERATION.
This electronic thermocontroller for packaged units manages ventilation air ows.
The unit is switched on or off by pressing and holding the 1 button. During operation
the display shows the set speed alternating with unit status, led 9.
When the unit is off, the display also remains off.
The unit can be controlled MANUALLY or AUTOMATICALLY.
MANUAL mode
To access MANUAL mode, press the 2 button; when the 3 light comes on the function
is active. The 4-5 buttons are used to select one of the ve fan speeds, also active
when the ue is cold.
The motor is started in automatic mode by a mechanical thermostat (the display
shows WAIT), which is activated when the temperature is at least 45°C (xed value,
not modiable). The 6 led indicates that the thermostat contact is closed.
AUTOMATIC mode
To access AUTOMATIC mode, press the 2 button; when the 7 light comes on the function is active. Use the 5 button to set the speed.
The 4-5 buttons are used to select one of the ve fan speeds.
In automatic mode the COMFORT temperature can also be selected. Press the 4 button to access the COMFORT temperature setting
and then set the value using 4-5. This setting allows the user to reduce fan noise when the room temperature measured by the probe
inside the controller exceeds the comfort set point; the motor operates one speed lower (this mode has no effect in rst speed) and is
signalled by the 8 led.
LANGUAGE menu.
Pressing and holding the 2 button accesses the LANGUAGE menu, where the display language can be changed using the 4-5 buttons
(IT, EN, DE, FR). Pressing the 2 button briey again accesses the DISPLAY menu, where the brightness can be adjusted (between 10
and 150). Pressing the 2 button briey another time accesses the DEGREES menu, where the temperature display can be set as °C
or °F.
BUZZER menu
Pressing the 2 button briey a nal time accesses the buzzer menu, where audible buzzer can be enabled or disabled.
REMOTE CONTROL OPERATION:
The electronic controller for packaged units can be managed by an IR remote control.
The controller is switched on or off by pressing and holding the 11-12 buttons.
To switch from MANUAL to AUTOMATIC on the IR remote control press the 13-14 buttons. The LED corresponding to the operating
mode comes on, manual 3 or automatic 7.
A
A
OK
O1
TM
1 2 3 4
5
6
77
8
12
3 7 89
4 5
6