La Nordica Annabella [12/36] Control panel

La Nordica Annabella [12/36] Control panel
OFF
1
2
3
4
5
6
ENGLISH
Control panel
BUTTON
ON/OFF
DISPLAY OF VARIOUS
TEXT MESSAGES
TO ACCESS
THE MENU
TEMPERATURE
SETTING
Display iCons key
Indicates the receipt of the radio signal
On = during radio communication
O = no radio communication
Fixed on = serial input disabled
Indicates the status of the additional thermostat input (GND - I3)
It indicates fumes motor operation.
O = fumes motor disabled
On = fumes motor active
Flashing = breakdown
It indicates ducted motor operation
O = Motor disabled
On = Motor active
Flashing = the motor is running at minimum and in modulation
mode (additional input open)
1
It indicates tangential fan operation (where applicable)
O = not working
On = working
Flashing = motor at minimum
Indicates the activation of the F1 function (future set-up)
O = function disabled
On = function active
It indicates pellet feed motor operation
O = pellet feed motor disabled
On = pellet feed motor active
It indicates weekly programming functioning
Indicator on = weekly programming active
Indicator o = weekly programming disabled
Indicates the compensation function
O = the function is disabled
On = the function is active
Indicates the stove modulation
On = the stove is working at the set power
Flashing = the power at which the stove is working is dierent to
the power set, the stove is modulating (for various reasons)
Indicates the contact of the external additional thermostat
Contact closed: the contact of the external additional
thermostat is closed and the STBY
function is disabled
Contact open: the contact of the external additional
thermostat is open and the STBY
function is disabled
Flashing with closed
contact:
the contact of the external additional
thermostat is closed and the STBY
function is active
Flashing with open
contact:
the contact of the external additional
thermostat is open and the STBY
function is active
Indicates the presence of an alarm.
On: indicates the presence of an alarm
O: indicates the absence of alarms
Indicates the room temperature status
O = the T° read by the probe is above the set temperature
On = the T° read by the probe is below the set temperature
Tank probe
O = probe ok
On = broken probe (short circuit or open)
Flashing = modulation due to tank
ADJUSTMENT
OPERATING POWER
12