Hoshizaki FM-80KE-N [37/61] Error codes
![Hoshizaki FM-80KE-N [37/61] Error codes](/views2/1322964/page37/bg25.png)
Содержание
- Contents 2
- Fm 150ke 4
- S m z cd 4
- Wembiml 5
- Iiwmpwcb 6
- Mwiikiiiimm 6
- Fir ond tube type air codec 7
- Condenser 8
- Icc making 5î5rm 8
- Ouisi0e wi 8
- Л оi z 8
- Ice making system 9
- T ram ft 9
- Amperage 10
- H fm 80ke 11
- Fm 80ke n 12
- A fm 150ke n cm 140ke fm 150ke 50 n fm 120ke cm 110ke 50 13
- Construction 13
- B fm 80ke n 14
- Extruding head upper bearing housing lower bearing 15
- Ii maintenance and cleaning instructions 15
- Important 15
- Mechanical seal 15
- Air filter air cooled model only 16
- Condenser air cooled model only 16
- Gear motor 16
- Control water valve 17
- Caution 18
- Cleaning of water system 18
- Important 18
- Warning 18
- Important 20
- A fm 150ke n cm 140ke fm 150ke 50 n fm 120ke cm 110ke 50 21
- Iii technical information 21
- Water circuit and refrigerant circuit 21
- B fm 80ke n 22
- A wiring diagram 23
- Fm 150ke n cm 140ke fm 150ke 50 n fm 120ke cm 110ke 50 23
- G1or cot 23
- Set no 23
- Wiring diagram 23
- B control box layout 25
- Cm 110ke cm 140ke 26
- Fm 80ke fm 120ke fm 150ke 50 26
- Fm 80ke n fm 150ke 50 n 26
- Icemaking mechanism 26
- A evaporator casing 27
- B auger 27
- C extruding head bearing 27
- D housing 27
- E mechanical seal 27
- F coupling spline joint 27
- G gear motor 27
- H belt heater provided on some models 28
- I removable flange 28
- J sealing bolt 28
- A basic operation 29
- Caution 29
- Electric circuit 29
- B timing chart 30
- A operation buttons 31
- B setting model number 31
- Ice when pressed in the stop mode the unit is supplied with water and starts icemaking operation stop when pressed in the ice mode the unit stops icemaking operation and drains maintenance a used for various maintenance operations maintenance b used for model code setting operation switch power supply for the icemaker move it to the off position to shut down the unit for a long time 31
- Important 31
- Number until it matches the model number on the wiring label 31
- Operation 31
- Operation board 31
- Position 31
- Press and hold the maintenance b button and move the operation switch to the on 31
- Press the maintenance b button to complete the setting and start icemaking operation in 31
- Switch 31
- The ice mode 31
- The model number must be set at the time of replacement of the controller board check the model number specified on the wiring label improper setting may result in failure or inoperability 31
- To check the model number see next page 31
- When the display shows 99 release the maintenance b button 3 press the stop button to increase the number or press the ice button to decrease the 31
- C displaying compressor operating hours cycle time model 32
- Compressor operating hours 32
- Cycle time 32
- Model number 32
- Number and software version 32
- Software version 32
- A compressor operating hours 33
- Approximate ice production capacity 33
- B cycle time 33
- C model number 34
- Compressor operating hours 34
- D displaying error log 34
- D software version 34
- Error log 34
- Ongoing error 34
- E resetting error log 35
- F resetting compressor operating hours 35
- G reducing compressor starting time 35
- A indication 36
- Bin full 36
- Ice stop 36
- Protectors 36
- Service use only 36
- Error codes 37
- Interlock errors 37
- Non interlock errors 38
- A fm 150ke fm 150ke 50 39
- Performance data 39
- B fm 150ke n fm 150ke 50 n 40
- C cm 140ke 41
- D fm 120ke 42
- E cm 110ke 50 43
- Fm 80ke 44
- G fm 80ke n 45
- Iv service diagnosis 46
- No ice production 46
- Low ice production 48
- Others 48
- A service information 50
- Allowable compressor opening time and prevention of lubricant mixture 50
- Handling of handy flux r404a r134a 50
- Oil for processing of copper tubing r404a r134a 50
- R404a r134a 50
- Replacement copper tubing r404a r134a 50
- Service for refrigerant lines 50
- Service parts for r404a r134a 50
- Treatment for refrigerant leak r404a r134a 50
- V removal and replacement 50
- B refrigerant recovery 51
- C evacuation and recharge 51
- Evacuation vacuum pump and refrigerant charge r404a r134a 51
- R134a models 51
- Refrigerant leak check 51
- R404a models 52
- Brazing 53
- Compressor 53
- Danger 53
- Important 53
- Warning 53
- Important 54
- Expansion valve 55
- Important 55
- Warning 55
- Important 56
- Water regulating valve water cooled model only 56
- Belt heater 57
- Cutter 57
- Evaporator 57
- Evaporator assembly 57
- Extruding head 57
- Gear motor 58
- Housing and mechanical seal 58
- Important 58
- Warning 58
- Warning 59
- Control water valve 60
- Flush water valve 60
- A modification 61
- B replacement 61
- Controller board 61
- Important 61
Похожие устройства
- Hoshizaki FM-80KE-N Руководство по установке
- Hoshizaki FM-80KE-N Каталог оборудования Hoshizaki (англ.)
- Linnafrost R10 Инструкция по эксплуатации
- Linnafrost R10 Презентация Linnafrost
- ISA Il Gelataio 4(+4) T1 Инструкция по эксплуатации
- Hoshizaki IM-100WNE Инструкция по эксплуатации
- Hoshizaki IM-100WNE Руководство по эксплуатации
- Hoshizaki IM-100WNE Каталог оборудования Hoshizaki (англ.)
- Hoshizaki IM-240WNE Инструкция по эксплуатации
- Hoshizaki IM-240WNE Руководство по эксплуатации
- Hoshizaki IM-240WNE Каталог оборудования Hoshizaki (англ.)
- ISA Il Gelataio 8(+8) T1 Инструкция по эксплуатации
- Abat ШОК-4-1/1 Инструкция по эксплуатации
- Abat ШОК-4-1/1 Руководство по эксплуатации
- Abat ШОК-4-1/1 Руководство повара
- ISA Il Gelataio 8(+8) T2 Инструкция по эксплуатации
- Hoshizaki IM-65WNE Инструкция по эксплуатации
- Hoshizaki IM-65WNE Руководство по эксплуатации
- Hoshizaki IM-65WNE Каталог оборудования Hoshizaki (англ.)
- ISA Il Gelataio 8(+8) T3 Инструкция по эксплуатации
7 ERROR CODES Interlock Errors Code Error Condition Operation Reset EO Icemaking Water Leak cO error occurs 2 times in a row Whole unit stops Power supply Turn OFF Turn ON E1 Low Ice Production Icemaking cycle takes too long Whole unit stops Power supply Turn OFF Turn ON Whole unit stops Power supply Turn OFF Turn ON Whole unit stops Power supply Turn OFF Turn ON With flush water valve OFF float switch trips at both upper and lower float levels for 2 seconds Gear motor is ON with rotation sensor or current sensor circuit open Gear motor relay is ON with gear motor protective circuit detector OFF Check Repair Water leak from water circuit reservoir inlet hose outlet hose hose joint mechanical seal flush water valve float switch Gas leak control water valve not closing vapor lock freeze float switch E2 Float Switch Error E3 Gear Motor Error or Gear Motor Sensor Circuit Open E4 Abnormal High Side Pressure c2 error occurs 5 times in 1 hour of compressor operation E4 blinks N A Gear Motor Drive Element Error Gear motor is OFF on controller board while rotation sensor signals gear motor rotation or current flows Gear motor relay is OFF with gear motor protective circuit detector ON Whole unit stops Power supply Turn OFF Turn ON Miswiring gear motor magnet switch or relay Replace controller board Discharge pipe thermostat is OFF Whole unit stops Power supply Turn OFF Turn ON Gas leak compressor cooling fan failure Water thermistor circuit is open EA blinks N A Water thermistor Condenser thermistor circuit is open Whole unit stops Evaporator outlet thermistor circuit is open Whole unit stops E5 E8 EA Eb EC EE Discharge Pipe Temperature Error Water Thermistor Circuit Open Condenser Thermistor Circuit Open Evaporator Outlet Thermistor Circuit Open Gear Motor Error Rotation sensor detects reversing c5 error occurs 5 times Power supply Turn OFF Turn ON Power supply Turn OFF Turn ON Float switch Rotation sensor current sensor Gear motor protective circuit TPO overload etc gear motor relay Fan motor cooling water circuit refrigeration circuit condenser clogged water supply installation conditions Condenser thermistor Evaporator outlet thermistor Whole unit stops Power supply Turn OFF Turn ON Gear motor locked hunting or overloaded supply voltage high ambient temperature EF Abnormal Low Voltage c3 error occurs 3 times in 24 hours Whole unit stops Power supply Turn OFF Turn ON Supply voltage EH Discharge Pipe Thermistor Circuit Open Discharge pipe thermistor circuit is open EH blinks N A Discharge pipe thermistor EL Bin Control Switch Error Bin control protective switch trips Whole unit stops Power supply Turn OFF Turn ON Bin control switch 34