Hytera RD-985 [20/24] Over low voltage alarm

Hytera RD-985 [20/24] Over low voltage alarm
19
loose or damaged. If yes, secure or replace the cable or antenna feeder.
3. If you cannot solve the problem, contact your local dealer for technical support.
When the VSWR falls within the normal range, the prompt message will disappear, and
the Alarm Indicator will go out.
Low Forward Power Alarm
When the forward power is below the preset value, the Alarm Indicator will glow red and
the LCD will display the prompt message below:
Then the repeater may continue transmission or terminate it, subject to the detection
result. You need to:
1. Check if the connection between the transmitter and RF cable or antenna feeder is
loose or damaged. If yes, secure or replace the cable or antenna feeder.
2. If you cannot solve the problem, contact your local dealer for technical support.
When the forward power is recovered to its normal value, the prompt message will
disappear, and the Alarm Indicator will go out.
Over/Low Voltage Alarm
When power voltage is detected to be over or below the normal range (11V-15.6V) of
repeater, the Alarm Indicator will glow red and the LCD will display the prompt message
below: