Hytera RD-985 [21/24] Troubleshooting

Hytera RD-985 [21/24] Troubleshooting
20
Low Voltage Alarm Over Voltage Alarm
Then the repeater will automatically stop working. You need to:
1. Check whether the power voltage is too low or too high. If yes, replace the DC power
supply or backup battery.
2. Check whether the power cord is loose or damaged. If yes, secure or replace the cord.
3. If you cannot solve the problem, contact your local dealer for technical support.
When the voltage falls within the normal range, the prompt message will disappear, and
the Alarm Indicator will go out.
Caution: If low voltage is detected when the repeater is powered by a backup battery,
you need to charge it with an external charger. Remove the battery from the
repeater before charging.
Troubleshooting
Phenomena
Analysis
Solution
The repeater
cannot be
a. Power cord is not connected
or is not securely connected
a. Properly connect the power cord
and ensure secure connection.