BEST K 508L [2/28] English

BEST K 508L [2/28] English
ENGLISH
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to 3rd speed after 5 minutes of operation to optimise energy consumption.
- If the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it will automatically
switch to OFF condition with all services switched off.
- The Buzzer emits a “beep” each time that a command is set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood, if you restore the hood in the OFF state, then the engine must be
reactivate manually.
DESCRIPTION
The hood may be in the filtering or the ducting version.
Filtering version: the hood aspirates the kitchen air saturated with fumes and odours, purifies it through the grease filters
and charcoal filter and returns clean air into the room. For constant efficiency, the charcoal filter must be replaced
periodically; the charcoal filter is not supplied.
If your extractor hood is the filter version, bear in mind that:
- if wall-mounted units are installed at the sides of the extractor hood, so that the slots on the hood may be obstructed
(Fig. 1), procure a rigid hose (T) fitted with a 45° coupling at the top end; the tube is not supplied. In this case, the
extractor hood should be installed before fittine the wall-mounted units and, when installation is complete, the upper
part of the hood must not be obstructed by the ceiling, the wall-mounted units or other items.
- if, on the other hand, the slots on the hood are not obstructed by wall-mounted units (Fig. 2), a baffle (A) and a flange
(B) are required; the baffle and flange are NOT supplied: order them from your retailer.
Ducting version (Fig. 3): the hood aspirates the kitchen air saturated with fumes and odours, passes it through the grease
filters and expels it to the outside through an outlet pipe. With this version the charcoal filter is not required. Decide from
the outset on the type of installation (filtering or ducting).
For greater efficiency, we recommend you install the hood in the ducting version (if possible).
WARNING: FAILURE TO INSTALL THE SCREWS OR FIXING DEVICE IN ACCORDANCE WITH THESE INSTRUCTIONSMAY
RESULT IN ELECTRICAL HAZARDS.
INSTALLATION
ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.
INSTALLATION IN DUCTING VERSION:
Before fixing, the outlet pipe for air evacuation to the outside must be installed. Use an outlet pipe with: – minimum
indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified material (according to the State);
– an as smooth as possible inside. It is also advisable to avoid any drastic changes in pipe cross-section (recommended
diameter: 150 mm). For air evacuation to the outside, follow all the other instructions given on the “Warnings” sheet. Prepare
the power supply within the telescopic chimney (for the electrical connection, follow all the other instructions on the
“Warnings” sheet).
1. Turn the upper telescopic flue around so that the slots face downwards (Fig. 4).
2. Install the flange in the device air outlet and press slightly (Fig. 5). Connect a flex pipe to the air outlet mouth of
the extractor hood and secure it with a metal retainer clamp (the pipe and band are not supplied) - Fig. 5.
3. Draw a line on the wall in vertical line with your hob. Mark the 4 holes to be drilled in the wall, respecting the distances
indicated in Fig. 6. Drill the holes and fit the screw anchors provided. As already specified on the “Warnings” sheet, bear
in mind that the distance between the lower edge of the hood and the hob must be min. 650 mm. Fix the metal bracket
(A) to the wall using 2 holes (B) just drilled (Fig. 7); the screws for fixing the bracket are provided. Use the 2 cut-out triangles
on the bracket to position it exactly along the vertical axis of the hood.
4. Hang the hood on the bracket (Fig. 8). Adjust the horizontal position moving the hood to the right or left so that it
is aligned with the wall units. Fix the hood with 2 screws (C).
5 Secure the bracket to the ceiling or the wall so that it is aligned with your extractor hood (Fig. 9).
6. Connect the flex pipe to the air evacuation hole in the wall (Fig. 10).
7. Make the electrical connection of the hood by means of the power cable (Fig. 10).
8. Raise the upper flue as far as the ceiling and secure it with two screws - Fig. 11.
INSTALLATION IN FILTERING VERSION:
1. Arrange the electric power supply inside the decorative flue (for the electrical connection, follow all the other
instructions given in the “Warnings” leaflet.
2. Draw a line on the wall vertical to your hob. Mark the 4 holes you need to drill in the wall respecting the measurements
indicated in Fig. 6. Make the holes and insert the screw anchors (provided). As specified in the “Warnings” leaflet, bear
in mind that the distance between the lower edge of the hood and the hob must be at least 650 mm. Fasten the metal
Скачать