IS356 ECN3592 12
6. Remove the nuts holding the drain tap to the drain tap bracket. Lift out safety lock arms. Undo the limit
stat nuts and free the limit stats. Disconnect limit stat wiring to interrupted t/couples. Disconnect control
stat wiring.
7. Unscrew flue at back. Body and hob are interlocked by 3 formed steel hook and slots each side – to
separate, push hob top back until hooks disengage, and then lift hob and tank assembly clear of base and
sides.
8. Take care, as the limit thermostat and safety stat will remain attached to hob top – do not damage
capillaries.
9. Carry out any work necessary and reassemble in the reverse order of 1-7 above.
Pilot Assembly.
To access the pilot assembly, firstly remove the control panel as per Step 4 above. Either pilot assembly can
then be lowered through the base of the unit by unscrewing the appropriate pilot box from beneath the unit,
and loosening the pilot pipe at the valve joint. Carefully remove the pilot box - all pilot components can then
be accessed.
Thermocouple.
1. Loosen retaining nut at valve.
2. Loosen retaining nut at pilot assembly.
3. Disconnect cabling from the interrupter.
4. Withdraw thermocouple from pilot assembly.
5. Replace as above in reverse order.
Thermopile
1. Disconnect thermopile lead at valve.
2. Loosen retaining nut at pilot assembly
3. Withdraw thermopile from pilot assembly.
4. Replace as above in reverse order.
Limit Thermostat.
1. Loosen tank gland.
2. Remove drain valve safety latch.
3. Loosen limit thermostat nut and withdraw from bracket. Disconnect wiring.
4. Withdraw probe from tank
5. Thermostat can now be removed.
6. Replace as above in reverse order.
Control Valve
1. Disconnect all wire connections on valve terminals.
2. Disconnect interrupted thermocouple from valve.
Содержание
- Silverlink 600 gas fryer 1
- User and installation instructions 1
- Warning parts which have been protected by the manufacturer or his agent must not be adjusted by the installer or user installation must include sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which they are installed 3
- Please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit 9
- Has electrode insulator fractured 14
- If no spark is generated at all 14
- Is there a short in the high tension 14
- Replace electrode 14
- Replace lead 14
- Replace piezo ignitor 14
Похожие устройства
- Lincat DF7pFL Каталог оборудования Lincat (англ.)
- Lincat C6H/100S Инструкция по эксплуатации
- Lincat C6H/100S Каталог оборудования Lincat (англ.)
- Lincat GG1P Инструкция по эксплуатации
- Lincat GG1P Каталог оборудования Lincat (англ.)
- Гриль-мастер Ф6ПДКЭ Инструкция по эксплуатации
- Гриль-мастер Ф6ПДКЭ Сертификат
- Lincat GG1R Инструкция по эксплуатации
- Lincat GG1R Каталог оборудования Lincat (англ.)
- Lincat EB6FX Инструкция по эксплуатации
- Lincat EB6FX Каталог оборудования Lincat (англ.)
- Lincat GR3FL Инструкция по эксплуатации
- Lincat GR3FL Каталог оборудования Lincat (англ.)
- Lincat GR7pFL Инструкция по эксплуатации
- Lincat GR7pFL Каталог оборудования Lincat (англ.)
- Lincat GR3nFL Инструкция по эксплуатации
- Lincat GR3nFL Каталог оборудования Lincat (англ.)
- Lincat GS4EFL Инструкция по эксплуатации
- Lincat GS4EFL Каталог оборудования Lincat (англ.)
- Bomann KM 1373 CB титан Инструкция по эксплуатации