Lincat DF7pFL [9/17] Please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit
![Lincat DF7pFL [9/17] Please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit](/views2/1337513/page9/bg9.png)
IS356 ECN3592 9
LIGHTING of the APPLIANCE.
Please ensure that the gas isolation valve for the appliance is turned to the open position before
attempting to light this unit.
1. Ensure that the thermostat control knob (Fig 2, 1) is in the OFF position.
2. Ensure the gas valve control knob (Fig 2, 2) is in the off position (Fig 3, A). Push in and turn anti-
clockwise to the Pilot position (Fig 3, B). The knob will now depress further.
3. Keeping the pilot control knob depressed, press the piezo ignition button (Fig 2, 3).
4. Ensure the pilot flame is alight, a blue flame can be seen when looking into the pilot viewing window
(Fig 2, 4). Hold the pilot control knob in for 20 seconds to establish the pilot flame.
5. When the pilot is lit, release the pilot control knob and continue to turn fully anti-clockwise to the ON
position (Fig 3, C).
6. If the pilot flame fails to remain lit, return the pilot control knob to the off position and repeat the process
allowing a short period of time for the control to reset.
7. To operate the main burner, turn the thermostat control knob (Fig 2, 1) to the required temperature
setting.
Fig 3
O
F
F
PILOT
O
N
O
F
F
PILOT
O
N
O
F
F
P
I
L
O
T
ON
A
B C
Standby
Once the pilot is lit the appliance may be left on standby by leaving the pilot control knob in the pilot ignition
position. (Fig 3, B). When in this position the appliance cannot be operated from the thermostat control knob.
To re ignite the main burners turn the pilot control knob anti-clockwise to the burner position, (Fig 3, C), and
operate the control thermostat as normal.
Note: Should the safety cut-out thermostat operate during normal use the unit will shut down. To re-
light the unit allow the oil to cool to a temperature below 200
o
C. Re-set the safety thermostat by
depressing the red re-set button. (Fig 2, 8).
SHUT DOWN OF THE APPLIANCE
1) When the appliance is not required, turn the thermostat fully anti-clockwise which will shut down the
main burner but leave the pilot lit ready for when the appliance is next required.
2) To turn the unit off completely, turn the thermostat fully anti-clockwise and the pilot knob fully
clockwise.
DRAINAGE
1) Always allow the oil to cool to a maximum 55
o
C before draining.
2) Remove the blanking nuts from the front of the unit (Fig 2, 5). Fit the pipe which is normally stowed in
the lid and place a suitable receptacle under the pipe outlet. Lift the safety catch (Fig 2, 7) and operate the
Содержание
- Silverlink 600 gas fryer 1
- User and installation instructions 1
- Warning parts which have been protected by the manufacturer or his agent must not be adjusted by the installer or user installation must include sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which they are installed 3
- Please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit 9
- Has electrode insulator fractured 14
- If no spark is generated at all 14
- Is there a short in the high tension 14
- Replace electrode 14
- Replace lead 14
- Replace piezo ignitor 14
Похожие устройства
- Lincat DF7pFL Каталог оборудования Lincat (англ.)
- Lincat C6H/100S Инструкция по эксплуатации
- Lincat C6H/100S Каталог оборудования Lincat (англ.)
- Lincat GG1P Инструкция по эксплуатации
- Lincat GG1P Каталог оборудования Lincat (англ.)
- Гриль-мастер Ф6ПДКЭ Инструкция по эксплуатации
- Гриль-мастер Ф6ПДКЭ Сертификат
- Lincat GG1R Инструкция по эксплуатации
- Lincat GG1R Каталог оборудования Lincat (англ.)
- Lincat EB6FX Инструкция по эксплуатации
- Lincat EB6FX Каталог оборудования Lincat (англ.)
- Lincat GR3FL Инструкция по эксплуатации
- Lincat GR3FL Каталог оборудования Lincat (англ.)
- Lincat GR7pFL Инструкция по эксплуатации
- Lincat GR7pFL Каталог оборудования Lincat (англ.)
- Lincat GR3nFL Инструкция по эксплуатации
- Lincat GR3nFL Каталог оборудования Lincat (англ.)
- Lincat GS4EFL Инструкция по эксплуатации
- Lincat GS4EFL Каталог оборудования Lincat (англ.)
- Bomann KM 1373 CB титан Инструкция по эксплуатации