Lincat DF7pFL [14/17] Has electrode insulator fractured
![Lincat DF7pFL [14/17] Has electrode insulator fractured](/views2/1337513/page14/bge.png)
IS356 ECN3592 14
TROUBLESHOOTING
FAULT FINDING
Explanation of the Control System
The gas circuit in this fryer is operated by two millivolt systems.
The first consists of an interrupted thermocouple, the pilot burner and the gas control.
Heat from the pilot flame acting on the thermocouple generates a 15-30 mV electrical potential.
This millivolt system connected to the gas control operates the first solenoid that allows gas to the pilot
burner. The over temperature stat is included in this system which operates via the interrupted thermocouple.
The first solenoid operates as the safety device which shuts down in the event of a thermocouple failure or if
the over temperature stat goes open circuit.
The secondary millivolt system consists of a thermopile acting through the gas control via the control
thermostat.
Heat from the pilot flame acting on the thermopile generates a 500-700 mV electrical potential.
This millivolt system connected to the gas control operates the secondary solenoid that passes gas to the main
burners.
The system is interrupted by the control thermostat as it cycles, thereby opening and closing the gas supply to
the main burners.
The following trouble shooting flow charts are designed to give assistance on the most probable cause of
failure of the gas circuit.
Use the step-by-step instructions to quickly pinpoint problems and the advice to help in taking the appropriate
action to rectify them.
Piezo Igniter not sparking.
Is there a short in the High Tension
Lead.
Replace Electrode.
Yes.
If no spark is generated at all,
replace Piezo Ignitor.
No.
Has Electrode Insulator Fractured.
No
Yes.
Replace Lead.
Содержание
- Silverlink 600 gas fryer 1
- User and installation instructions 1
- Warning parts which have been protected by the manufacturer or his agent must not be adjusted by the installer or user installation must include sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which they are installed 3
- Please ensure that the gas isolation valve for the appliance is turned to the open position before attempting to light this unit 9
- Has electrode insulator fractured 14
- If no spark is generated at all 14
- Is there a short in the high tension 14
- Replace electrode 14
- Replace lead 14
- Replace piezo ignitor 14
Похожие устройства
- Lincat DF7pFL Каталог оборудования Lincat (англ.)
- Lincat C6H/100S Инструкция по эксплуатации
- Lincat C6H/100S Каталог оборудования Lincat (англ.)
- Lincat GG1P Инструкция по эксплуатации
- Lincat GG1P Каталог оборудования Lincat (англ.)
- Гриль-мастер Ф6ПДКЭ Инструкция по эксплуатации
- Гриль-мастер Ф6ПДКЭ Сертификат
- Lincat GG1R Инструкция по эксплуатации
- Lincat GG1R Каталог оборудования Lincat (англ.)
- Lincat EB6FX Инструкция по эксплуатации
- Lincat EB6FX Каталог оборудования Lincat (англ.)
- Lincat GR3FL Инструкция по эксплуатации
- Lincat GR3FL Каталог оборудования Lincat (англ.)
- Lincat GR7pFL Инструкция по эксплуатации
- Lincat GR7pFL Каталог оборудования Lincat (англ.)
- Lincat GR3nFL Инструкция по эксплуатации
- Lincat GR3nFL Каталог оборудования Lincat (англ.)
- Lincat GS4EFL Инструкция по эксплуатации
- Lincat GS4EFL Каталог оборудования Lincat (англ.)
- Bomann KM 1373 CB титан Инструкция по эксплуатации