COMPONENT REPLACEMENT
Access to gas circuit components can be made when the hood and side panel are removed
as described earlier.
Burner
Remove the six burner retaining screws (not shown) and lift the burner Z from the
support bracket.
Fit the new burner.
Injector
The burner injector Y can be
removed separately using a ¼"
AF spanner.
Replace the copper washer
(CO113) and fibre washer
(WA08) when fitting a new
injector.
Thermocouple
Loosen the thermocouple lock
nut N at the valve body O.
Remove the two thermocouple
mounting screws at the burner
support bracket.
Draw the thermocouple capillary through the body.
Fit new thermocouple and re-assemble components.
Valve
Loosen the burner feed pipe nut T and the thermocouple lock nut N.
Remove the control knob R from the valve spindle.
Loosen the valve clamp screws from the manifold.
Free the valve from the pipe work and manifold.
Remove the burner feed compression fitting from the valve and fit to the new valve
with a suitable thread sealant (Loctite 577 recommended).