INSTALLATION INSTRUCTIONS
Before commencing installation of the appliance, please take time to read the installation instructions
carefully.
All appliances should be installed in accordance with BS 6173, Code of practice for installation of gas
catering appliances, taking into account the Gas Safety Regulations as amended by the Gas Safety
(Installation and Use)(Amendment) Regulations and the Health and Safety at Work Act.
It is mandatory that all appliances are installed and commissioned by a qualified and competent CORGI
registered gas fitter. WARNING: Installation, service or repair of this appliance by non-CORGI registered
personnel may invalidate its warranty.
1.1 VENTILATION
The area in which this equipment is to be installed should have sufficient fixed ventilation to comply with
the requirements of Approved Document J in the 2002 Building Regulations. It is recommended that a
minimum area of 450mm
2
per 1kWh (3400Btu/hr) of total heat input must be allowed. Particular attention
should be paid to the low-level ventilation to ensure that the appliance has a good supply of clean, fresh
air.
1.2 INSTALLATION POSITION
The unit must be mounted on a work surface or stand, which must have either a metal or open top.
There should be a minimum clearance of 750mm between the top of the appliance and any overlying
shelf or ceiling.
Where the unit is to be free standing, any partitions, walls or kitchen furniture in close proximity (at least
50mm clearance given on all sides) must be of non-combustible materials.
1.3 INSTALLATION COMMISSIONING
To ensure a full understanding of the correct operation of the appliance the following commissioning
checks must be carried out before the appliance is handed over for use.
All operators must know how to light, safely operate and shutdown the appliance.
Although all Lincat griddles are functionally checked during manufacture, commissioning should include
an operational check of all controls.
Ensure that the unit is level.
Before use, remove all protective plastic coating from the unit.
1.4 GAS SUPPLY & CONNECTION
Check that the gas supply corresponds to that specified on the data plate.
Connection is via a 1/2" bspt male thread on the back of the unit. If connection to the supply pipe is via a
flexible hose, ensure that the hose used is suitable for commercial catering appliances. The hose should
be periodically examined and replaced as necessary.
WARNING: Black domestic hoses are not suitable for this appliance.
When making the connection on to the appliance, secure the hexagon on the fitting to prevent rotation of
the internal pipe work. An isolating cock should be fitted into the supply line to the unit for servicing
purposes.
Содержание
- Silverlink 600 gas griddles gs4 and gs7 1
- User installation and servicing instructions 1
- Installation and servicing instructions 2
- Gs4 units gs4 units 3
- Gs7 units 3
- Natural gas g20 supply pressure 20mbar 3
- Propane gas g31 supply pressure 30 50 mbar 3
- Technical data 3
- Contents 4
- Foreword 5 4
- Installation instructions 6 7 4
- Operating instructions 8 4
- Service information 12 4
- Servicing 9 10 4
- Troubleshooting 11 4
- Consequential loss 5
- Foreword 5
- Important please read this page carefully before using the equipment warning it is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation failure to comply will invalidate the warranty 5
- Maintenance 5
- Gas supply connection 6
- Installation commissioning 6
- Installation instructions 6
- Installation position 6
- Ventilation 6
- Heat input 7
- Pressure setting 7
- Care of griddle plates 8
- Do not use sharp cornered instruments on a chromed griddle surface 8
- Lighting the appliance 8
- Operating instructions 8
- Preparation for use 8
- Shut down of appliance 8
- Warnin 8
- Component replacement 9
- General service 9
- Please see page 12 service for information on authorised service agents 9
- Servicing 9
- Spares list 10
- Troubleshooting 11
- 01522 875 520 12
- Authorised service agents 12
- Conditions of guarantee 12
- Contact information 12
- Guarantee statement 12
- Lincat service help desk 12
- Service information 12
Похожие устройства
- Lincat GS7pFL Каталог оборудования Lincat (англ.)
- Lincat GS7/RpFL Инструкция по эксплуатации
- Lincat GS7/RpFL Каталог оборудования Lincat (англ.)
- Lincat HC3FL Инструкция по эксплуатации
- Lincat HC3FL Каталог оборудования Lincat (англ.)
- Lincat GS7/RnFL Инструкция по эксплуатации
- Lincat GS7/RnFL Каталог оборудования Lincat (англ.)
- Lincat GS7FL Инструкция по эксплуатации
- Lincat GS7FL Каталог оборудования Lincat (англ.)
- Lincat GS7nFL Инструкция по эксплуатации
- Lincat GS7nFL Каталог оборудования Lincat (англ.)
- Lincat HC4FL Инструкция по эксплуатации
- Lincat HC4FL Каталог оборудования Lincat (англ.)
- Lincat HC6FL Инструкция по эксплуатации
- Lincat HC6FL Каталог оборудования Lincat (англ.)
- Lincat HC7FL Инструкция по эксплуатации
- Lincat HC7FL Каталог оборудования Lincat (англ.)
- Bugatti VERA EASY Chrome Инструкция по эксплуатации
- Bugatti VERA EASY Black Инструкция по эксплуатации
- Airhot SV-30 Инструкция по эксплуатации