Lincat GS7pFL [9/12] Servicing
![Lincat GS4nFL [9/12] Servicing](/views2/1337534/page9/bg9.png)
IS212 ECN3592
9
SERVICING
Gas catering equipment should be routinely serviced to ensure a long trouble-free life. With this in mind, it is
recommended that a competent gas engineer service the appliances every 6 months.
Please see page 12 “Service” for information on authorised service agents.
3.1 GENERAL SERVICE
General check of the equipment, e.g. installation - is the unit on the correct hose? Does the hose have
a safety chain? Does the equipment have a separate isolation valve?
To access the valve/s, pull off the knobs and remove screws from the facia panel.
Lower the fascia panel to reveal the valves.
Check and adjust where necessary the burner pressure at the test nipple, with the unit in full
operation.
Check the general burner condition.
Check the thermocouple/s for sooting etc. and clean. Check for correct operating distance (3mm
from the centre of the thermocouple to the burner face).
Carryout a gas soundness check.
Refit the fascia panel and the control knob/s.
3.2 COMPONENT REPLACEMENT.
Note: When removing the control knob care must be taken not to lose the spring clip.
3.2.1 Thermocouple
Remove the fat drawer, control knobs and fascia panel.
Remove the rear panel.
Slide the hob top / griddle plate backwards and lift off. This assembly is very heavy and Lincat
advises this is a two-person job.
Loosen the thermocouple-retaining nut at the valve.
Loosen the retaining nuts on the thermocouple body.
Withdraw the thermocouple from the bracket.
Refitting is the reverse of the above.
Check for correct operating distance (3mm from the centre of the thermocouple to the burner
face).
3.2.2 Control Valve
Remove knobs and fascia panel.
Remove the thermocouple from the back of the valve.
Loosen the nuts to burner feed pipe.
Loosen the valve retaining screws.
Fit the new valve and thermocouple and leak test the unit.
Check the gas pressure.
Note: The control valve has been factory pre-set and therefore it should not be necessary to adjust the
low flame setting.
3.2.4 Burner
Remove knobs and fascia panel.
Remove the rear panel.
Slide the hob top / griddle plate backwards and lift off. This assembly is very heavy and Lincat
advises this is a two-person job.
Содержание
- User installation and servicing instructions p.1
- Silverlink 600 gas griddles gs4 and gs7 p.1
- Installation and servicing instructions p.2
- Technical data p.3
- Propane gas g31 supply pressure 30 50 mbar p.3
- Natural gas g20 supply pressure 20mbar p.3
- Gs7 units p.3
- Gs4 units gs4 units p.3
- Troubleshooting 11 p.4
- Servicing 9 10 p.4
- Service information 12 p.4
- Operating instructions 8 p.4
- Installation instructions 6 7 p.4
- Foreword 5 p.4
- Contents p.4
- Important please read this page carefully before using the equipment warning it is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation failure to comply will invalidate the warranty p.5
- Foreword p.5
- Consequential loss p.5
- Maintenance p.5
- Ventilation p.6
- Installation position p.6
- Installation instructions p.6
- Installation commissioning p.6
- Gas supply connection p.6
- Pressure setting p.7
- Heat input p.7
- Warnin p.8
- Shut down of appliance p.8
- Preparation for use p.8
- Operating instructions p.8
- Lighting the appliance p.8
- Do not use sharp cornered instruments on a chromed griddle surface p.8
- Care of griddle plates p.8
- Component replacement p.9
- Servicing p.9
- Please see page 12 service for information on authorised service agents p.9
- General service p.9
- Spares list p.10
- Troubleshooting p.11
- Service information p.12
- Lincat service help desk p.12
- Guarantee statement p.12
- Contact information p.12
- Conditions of guarantee p.12
- Authorised service agents p.12
- 01522 875 520 p.12
Похожие устройства
-
Lincat LGR2Каталог оборудования Lincat (англ.) -
Lincat LGR2Инструкция по эксплуатации -
Lincat GS7nFLКаталог оборудования Lincat (англ.) -
Lincat GS7nFLИнструкция по эксплуатации -
Lincat GS7FLКаталог оборудования Lincat (англ.) -
Lincat GS7FLИнструкция по эксплуатации -
Lincat GS7/RnFLКаталог оборудования Lincat (англ.) -
Lincat GS7/RnFLИнструкция по эксплуатации -
Lincat GS7/RpFLКаталог оборудования Lincat (англ.) -
Lincat GS7/RpFLИнструкция по эксплуатации -
Lincat GS7pFLКаталог оборудования Lincat (англ.) -
Lincat GS65FLКаталог оборудования Lincat (англ.)