Lincat HT6nFL [4/16] Technical data

Lincat HT6pFL [4/16] Technical data
IS 513 ECN 3706 Page 4 of 16
TECHNICAL DATA
Model
HT3 HT6 HT9
Overall Height (mm)
305
Width (mm)
300 600 900
Depth (mm)
600
Weight (kg)
16 28 32
Total Heat Input Natural (Gross)
9.0kW 18.0kW 27.0kW
Total Heat Input Propane (Gross)
9.0kW 18.0kW 27.0kW
Total Heat Input Butane (Gross)
7.4kW 14.8kW 22.2kW
Gas Inlet Connection
½" BSP (R
p
½)
Supply Pressure - Natural
20mbar
Supply Pressure - Propane
37mbar
Supply Pressure - Butane
28-30mbar (29mbar)
Individual Burner Heat Input Full Rate
Natural
4.5kW
Propane
4.5kW
Butane
3.7kW
Individual Burner Heat Input Low Rate
Natural
0.85kW
Propane
0.85kW
Butane
0.85kW
Gas Consumption Full Rate
Total Gas Rate – Natural
0.86m
3
h
-
1
1.72m
3
h
-
1
2.57m
3
h
-
1
Total Gas Rate – Propane
0.64kgh
-
1
1.29kgh
-
1
1.93kgh
-
1
Total Gas Rate – Butane
0.54kgh
-
1
1.08kgh
-
1
1.62kgh
-
1
Individual Burner Gas Consumption Full Rate
Gas Rate – Natural
0.43m
3
h
-
1
Gas Rate – Propane
0.32kgh
-
1
Gas Rate – Butane
0.27kgh
-
1
Gas Consumption Low Rate
Total Gas Rate – Natural
0.16m
3
h
-
1
0.32m
3
h
-
1
0.49m
3
h
-
1
Total Gas Rate – Propane
0.12kgh
-
1
0.24kgh
-
1
0.36kgh
-
1
Total Gas Rate – Butane
0.12kgh
-
1
0.25kgh
-
1
0.37kgh
-
1
Individual Burner Gas Consumption Low Rate
Total Gas Rate – Natural
0.08m
3
h
-
1
Total Gas Rate – Propane
0.06kgh
-
1
Total Gas Rate – Butane
0.06kgh
-
1

Содержание

Скачать