Lincat HT6pFL [13/16] Fault finding

Lincat HT6pFL [13/16] Fault finding
IS 513 ECN 3706 Page 13 of 16
Burner not lighting
Not all burner ports are lit
Note: Gas not burning at all the burner ports can occur after a spillage or boil over where
water has collected in the burner ports.
Burners will not remain lit
FAULT FINDING
Burner not lighting
Turn on gas supply
or
interlock switch
Burner lights but will not remain lit
Call Service Agent
Check thermocouple mV outputCheck thermocouple connection
Tighten connection
Replace thermocouple
OK
Replace valve
Burner lights but not all ports are lit
Check burner ports for blockages Clean burner ports
Call Service Agent OK