IS 513 ECN 3706 Page 6 of 16
INSTALLATION AND COMMISSIONING
Site this appliance beneath an extraction canopy for the removal of combustion
products.
Installation must include sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room of
installation. There must be a minimum free area of 4.5cm
2
per kW of total heat
input.
Allow for a sufficient flow of fresh air for complete gas combustion.
Do not connect directly to any flue, ducting or mechanical extraction system.
The gas supply hose or tubing shall comply with national requirements in force and
shall be periodically examined and replaced as necessary.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
Install this appliance on a level surface ensuring all vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material and not be closer
than 50mm
Ensure there is a space of at least 1000mm between the working surface and any
ceiling.
GAS SUPPLY AND CONNECTION
Connection is at the rear of the unit via a R
p
½ (½" BSP)
When making the connection to the appliance an isolating cock should be fitted into the
supply line close to the unit, for emergency shutdown or servicing purposes.
SUPPLY PRESSURES
The appliances are intended to be connected directly to the gas supply without further
adjustment for those countries where the supply pressure does not exceed the pressures
as detailed above. For those countries where the supply pressures exceed the pressures
as tabled then the supply pressure must be regulated to the pressures as detailed above.
For the purposes of proving connection integrity access to the pressure test nipple is as
follows:
• To gain access to the gas pressure test nipple open the oven door/s.
• Remove the control knobs.
• Remove the anti-tamper screws securing the fascia
• Remove the oven ignitor lead.
• The test nipple is found on the manifold rail.
FIRST TIME LIGHTING
The procedure for first time lighting may only be carried out by registered personnel.
To light any individual burner it may be necessary to purge all pipe work of air.
To do this, depress and hold in the full on position as many controls knobs as possible
until there is evidence of free gas flow. Upon detection of gas flow return all but one control
knobs to the 'OFF' position and light the gas at the burner corresponding to the control
Содержание
- Installation operating servicing and conversion instructions silverlink 600 gas boiling tops ht3 ht6 ht9 1
- Contents 2
- Important information 2
- Keep this manual for future reference 2
- Warnings and precautions 3
- Butane 4
- Depth mm 4
- Gas consumption full rate 4
- Gas consumption low rate 4
- Gas inlet connection 4
- Gas rate butane 4
- Gas rate natural 4
- Gas rate propane 4
- Ht3 ht6 ht9 4
- Individual burner gas consumption full rate 4
- Individual burner gas consumption low rate 4
- Individual burner heat input full rate 4
- Individual burner heat input low rate 4
- Natural 4
- Overall height mm 4
- Propane 4
- Supply pressure butane 4
- Supply pressure natural 4
- Supply pressure propane 4
- Technical data 4
- Total gas rate butane 4
- Total gas rate natural 4
- Total gas rate propane 4
- Total heat input butane gross 4
- Total heat input natural gross 4
- Total heat input propane gross 4
- Weight kg 4
- Width mm 4
- Check list of enclosures 5
- Installation and commissioning 6
- Operating instructions 8
- Cleaning 9
- Servicing maintenance and component replacement 10
- Conversion 11
- Burner lights but not all ports are lit 13
- Burner lights but will not remain lit 13
- Burner not lighting 13
- Call service agent 13
- Call service agent ok 13
- Check burner ports for blockages clean burner ports 13
- Check supply pressure 13
- Check thermocouple mv output check thermocouple connection 13
- Fault finding 13
- Replace valve 13
- Tighten connection replace thermocouple ok 13
- Turn on gas supply or interlock switch 13
- Spare parts list 14
- Accessories 15
- Service information 16
Похожие устройства
- Lincat HT6pFL Каталог оборудования Lincat (англ.)
- Бирюса 146 Руководство пользователя
- Rock Kitchen HM-22A Инструкция по эксплуатации
- Rock Kitchen HM-22A Каталог Rock Kitchen HHD-05
- Rock Kitchen HM-22B Инструкция по эксплуатации
- Rock Kitchen HM-22B Каталог Rock Kitchen HHD-05
- Lincat HT7FL Инструкция по эксплуатации
- Lincat HT7FL Каталог оборудования Lincat (англ.)
- Lincat HT9pFL Инструкция по эксплуатации
- Lincat HT9pFL Каталог оборудования Lincat (англ.)
- Lincat J10pFL Инструкция по эксплуатации
- Lincat J10pFL Каталог оборудования Lincat (англ.)
- Lincat J10nFL Инструкция по эксплуатации
- Lincat J10nFL Каталог оборудования Lincat (англ.)
- Lincat J5nFL Инструкция по эксплуатации
- Lincat J5nFL Каталог оборудования Lincat (англ.)
- Lincat LBM2W Инструкция по эксплуатации
- Lincat LBM2W Каталог оборудования Lincat (англ.)
- Robot Coupe CL55 рабочая станция Инструкция по эксплуатации
- Robot Coupe CL55 рабочая станция Каталог оборудования Robot Coupe