Service & Sales
1-800-421-6150
www.wilburcurtis.com
BREWING ISSUES
TANK FILLING ISSUES
Does the LCD read “Water Level
Error”?
Verify the ow rate to be a minimum of 1
gpm from outlet of the water lter. If not,
ensure that the inlet side of the water
lter is receiving a minimum of 1 gpm. If
yes, replace the water lter. If not, con-
sult a plumber.
Remove the orange wire from the probe.
Does the tank start lling?
Replace water level probe
Replace the UCM
Turn OFF toggle switch.
Does the tank continue to ll?
Yes: Replace water inlet valve
No: Ground the probe wire to the chassis.
Does the tank continue to ll?
Yes: Replace the UCM
No: Replace Water Level Probe
Overlling:
Not lling:
Yes:
Yes:
No:
Yes:
No:
i
Before replacing any parts, verify the
following:
Verify that the Dump Valve outlet tting on the tank,
the tubing between the tank outlet and the Spray head
tting, the Spray head, and Dump Valve are clear of
obstructions.
Ensure correct alignment of the spray head tting and
that the tubing is routed properly to allow for maximum
water ow. (No Kinks)
LCD does not read “Brewing”:
If the LCD reads “Ready to Brew” and there is no
response when Brew Button is pressed, replace
the UCM.
LCD reads “Brewing”:
No water ow from the spray head:
Does water ow from the hot water faucet? If
yes, verify 120 volts at the dump valve coil. If
voltage is present at the dump valve coil, replace
the dump valve. If 120 volts is not present at
the dump valve coil, conrm continuity of wiring
between molex connector and Dump Valve. If
okay, replace the UCM. (Verify the resistance on
the dump valve coil to be open in one direction,
and under 2k ohm in the other direction BEFORE
REPLACING THE UCM) If water does not ow
from the hot water faucet, replace the Water Lev-
el Probe.
Brewing Short Pots:
Verify that the Hot Water Tank is lling correctly.
(See Tank Filling issues)
Overowing the Pot:
• Ensure that the Spray head has not been re-
moved. Replace as needed.
• Ensure that the Hot Water Tank is not over-
owing (See Tank Filling Issues)
• Ensure that hot water is not owing from the
Dump Valve when the toggle switch is turned
off. If it is, replace the dump valve.
• Ensure Cold Brew Lock is set to 5°F.
TROUBLESHOOTING INSTRUCTIONS
www.wilburcurtis.com
Содержание
- Curtis airpot brewer 1
- D500gt12a1000 1
- G3 single airpot coffee brewer dispenser sold separately 1
- Troubleshooting guide 1
- Brewer parts identification 3
- Heat related 3
- Master control 3
- Water related 3
- Parts images 4
- Heating issues 5
- Power issues 5
- Troubleshooting instructions 5
- Brewing issues 6
- Tank filling issues 6
- Troubleshooting instructions 6
- Wilbur curtis co inc 8
Похожие устройства
- Curtis CGCE Инструкция по эксплуатации
- Curtis CGCE Устранение неполадок (англ.)
- Curtis G4GEMTIF30A1000 Инструкция по эксплуатации
- Curtis WB5N30 Инструкция по эксплуатации
- Curtis TFT1G Инструкция по эксплуатации
- Carel UE003XL0E1 Инструкция по эксплуатации
- Curtis TP15T30A1100 Инструкция по эксплуатации
- Curtis TP15T30A1100 Устранение неполадок (англ.)
- Faber IN-NOVA SMART A60 (110.0395.198) Инструкция по эксплуатации
- Faber IN-NOVA SMART A60 (110.0395.198) Схема
- Faber IN-NOVA SMART A60 (110.0395.198) Каталог Faber
- Faber IN-NOVA COMFORT X A60 (110.0439.937) Инструкция по эксплуатации
- Faber IN-NOVA COMFORT X A60 (110.0439.937) Руководство по монтажу
- Faber IN-NOVA COMFORT X A60 (110.0439.937) Схема
- Faber IN-NOVA COMFORT X A60 (110.0439.937) Каталог Faber
- Green GRI/GRO-24 IH Инструкция по эксплуатации
- Green GRI/GRO-24 IH Сертификат
- Green GRI/GRO-24 IH Гарантийный талон
- Faber IN-NOVA PREMIUM X A60 (110.0439.940) Инструкция по эксплуатации
- Faber IN-NOVA PREMIUM X A60 (110.0439.940) Руководство по монтажу
Скачать
Случайные обсуждения