Commax JNS-4CM Инструкция по эксплуатации(ENG) онлайн [5/22] 283775
![Commax JNS-4CM Инструкция по эксплуатации(ENG) онлайн [5/22] 283775](/views2/1341851/page5/bg5.png)
5
5-2-2. Lift up the handset in Master station for communication. (Corridor Light will be off)
5-2-3. If the master station is on the line, it will automatically flash the green led on the bed for its
conversation. If press the call button, it will be reserved with the alarming of red lamp, and then it
will be automatically connected after the previous conversation.
55
-
-
4
4
.
.
P
P
r
r
e
e
s
s
e
e
n
n
c
c
e
e
s
s
w
w
i
i
t
t
c
c
h
h
5-4-1. For emergency case, the nurse put the presence switch to inform the location with corridor
lamp function and notifying to be reply for the master station's call.
5-4-2. If the presence switch is on, the corridor lamp will be on display the master station.
5-4-3. To cancel the presence switch, press the presence switch it again.
5-4-4. Under the presence status, communication or call will be STAFF CALL status.
5-4-5. When nurse goes into the patient room, press the presence S/W to turn on the white
corridor lamp. When nurse comes out from the patient room, press the presence S/W to turn off the
green LED then the presence will be canceled.
5
5
-
-
5
5
.
.
E
E
m
m
e
e
r
r
g
g
e
e
n
n
c
c
y
y
s
s
w
w
i
i
t
t
c
c
h
h
(
(
F
F
o
o
r
r
t
t
o
o
i
i
l
l
e
e
t
t
u
u
s
s
e
e
)
)
5-5-1. For emergency case, push the switch to announce the emergency.
5-5-2. If that case, the corridor Lamp is on, Display the master station with red lamp.
5-5-3. To cancel the emergency switch, press the emergency switch it again.
5
5
-
-
6
6
.
.
E
E
m
m
e
e
r
r
g
g
e
e
n
n
c
c
y
y
s
s
h
h
o
o
w
w
e
e
r
r
s
s
w
w
i
i
t
t
c
c
h
h
(
(
F
F
o
o
r
r
s
s
h
h
o
o
w
w
e
e
r
r
r
r
o
o
o
o
m
m
u
u
s
s
e
e
)
)
5-6-1 For emergency case, push the switch to announce the emergency.
5-6-2. If that case, the corridor Lamp is on, Display the master station with red lamp.
5-6-3. To cancel the emergency switch, press the emergency switch it again.
5
5
-
-
7
7
.
.
S
S
t
t
a
a
f
f
f
f
C
C
a
a
l
l
l
l
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
5-7-1. In emergency, nurse in a patient room can announce the emergency to nurse station through
the call button in sub station.
5-7-2. If the presence switch is in, white corridor lamp will be automatically lighted and red
corridor lamp will blink.
5-7-3. To cancel the presence switch press the off switch.
5-7-4. The conversation can be available when the master station receive the call, it will be a
presence position.
5
5
-
-
8
8
.
.
E
E
m
m
e
e
r
r
g
g
e
e
n
n
c
c
y
y
S
S
w
w
i
i
t
t
c
c
h
h
(
(
C
C
o
o
r
r
r
r
i
i
d
d
o
o
r
r
T
T
o
o
i
i
l
l
e
e
t
t
)
)
5-8-1. For emergency case, push the switch to announce the emergency, it can be connected 16
units with the master station.
5-8-2. If that case, the corridor lamp will be lighted. Display the master station with red lamp.
5-8-3. It will be alarmed directly from the master station, red LED in corridor toilet will blink.
5-8-4. To cancel the emergency switch, press the emergency switch it again.
5-9. Induction lamp
5
5
-
-
9
9
.
.
I
I
n
n
t
t
e
e
r
r
p
p
h
h
o
o
n
n
e
e
C
C
a
a
l
l
l
l
Interphone Call can communicate with other place or between nurse stations through installing
extra interphone or between master stations.
5-9-1.
Lift the handset, press the Interphone button and the number of room No. or Interphone No.
(If receiver's line is busy or is receiving, you can hear the busy tone or back tone.)
www.safemag.ru
www.safemag.ru
Содержание
- Commax nurescall syste 1
- Jjnnss 44ccm m 1
- User manual 1
- Www safemag ru 1
- Contents 2
- System features 3
- System introduction 3
- System specification 3
- Bed paging call xxxx 4
- Communication call xxxx 4
- Flashing white 4
- How to use and function 4
- Interphone 4
- Presence s w steady green steady white 4
- Section lcd led sound corridor light 4
- Signal and lamp specification 4
- Staff paging staff xx flushing ginger police sound steady white flashing red 4
- Steady green 4
- Toilet corridor emerg xxxx flashing red emer sound steady red 4
- Toilet room emerg xxxx flashing red emer sound flashing red 4
- Bed programming 7
- How to assign the common number 7
- Installation work 8
- 1 system diagram 11
- Nurse call system drawing 11
- 2 system wiring diagram 12
- 4 system connection schematic 14
Похожие устройства
- Commax DP-2HP Инструкция по эксплуатации(ENG)
- Telwin Digital modular 400 Инструкция по эксплуатации
- Telwin ALUSPOTTER 6100 AUTOMOTIVE Инструкция по эксплуатации
- Telwin ALUSPOTTER 6100 Инструкция по эксплуатации
- Telwin ETRONITHY 630 CE Инструкция по эксплуатации
- Telwin LINEAR 500 HD Инструкция по эксплуатации
- Telwin LINEAR 360/S Инструкция по эксплуатации
- Telwin MOTOINVERTER 254 CE HONDA Инструкция по эксплуатации
- Telwin MOTOINVERTER 184 CE HONDA Инструкция по эксплуатации
- Telwin TECNICA 114 ACX PLASTIC CARRY CASE Инструкция по эксплуатации
- Telwin TECNICA 144 ACX PLASTIC CARRY CASE Инструкция по эксплуатации
- Telwin SUPERIOR 300 CE Инструкция по эксплуатации
- Telwin TECHNOLOGY 220/S Инструкция по эксплуатации
- Telwin TECHNOLOGY TIG 180 AC/DC HF/LIFT Инструкция по эксплуатации
- Telwin TECHNOLOGY TIG 172 AC/DC HF/LIFT Инструкция по эксплуатации
- Pfaff SELECT 2.0 Инструкция по эксплуатации
- Pfaff SELECT 2.0 Краткий справочник
- Pfaff CREATIVE SENSATION PRO Инструкция по эксплуатации
- Pfaff CREATIVE PERFORMANCE Инструкция по эксплуатации
- Pfaff CREATIVE SENSATION Инструкция по эксплуатации