SERA fil bioactive 16Вт 300л/ч Инструкция по эксплуатации онлайн [17/110] 296132
![SERA fil bioactive 22Вт 1100л/ч Инструкция по эксплуатации онлайн [17/110] 296129](/views2/1355024/page17/bg11.png)
Содержание
- W w w w w w w w w w w w w w w w w w w w w w 1
- Sera fil bioactive 130 130 uv sera fil bioactive 250 250 uv 2
- Cebrauchsinformation sera fil bioactive außenfilter 130 130 uv 250 250 uv 400 uv 9
- I ic information for use sera fil bioactive external filters uo 130 130 uv 250 250 uv 400 uv 15
- Fil bioactive 130 130 uv 250 250 uv 400 uv 21
- Information mode d emploi filtres extérieurs 21
- I cebruikersinformatie sera fil bioactive buitenfilters iml 130 130 uv 250 250 uv 400 uv 27
- Fil bioactive filtro esterno 130 130 uv 250 250 uv 400 uv 33
- Informazioni per l uso 33
- Fil bioactive 130 130 uv 250 250 uv 400 uv 39
- Información para el usuario del filtro exterior 39
- Recomendaciones 43
- Fil bioactive 130 130 uv 250 250 uv 400 uv 45
- Instruções para utilização filtro exterior 45
- Produktinformation sera fil bioactive ytterfilter 130 130 uv 250 250 uv 400 uv 51
- 130 uv 250 250 uv 400 uv 57
- Käyttöohje sera fil bioactive ulkosuodattimille 57
- Nxnpckpopieq yi е штвр1кб фглтра sera fil bioactive 63
- Uk 130 130 uv 250 250 uv 400 uv 63
- Cl navodilo za uporabo sera fil bioactive zunanjega filtra i 130 130 uv 250 250 uv 400 uv 69
- 130 uv 250 250 uv 400 uv 75
- Upute za upotrebu sera fil bioactive vanjskog altera 75
- 130 uv 250 250 uv 400 uv 80
- Használati információ a sera fil bioactive külsö szüröhöz 80
- Di informacje о zastosowaniu 86
- Fil bioactive zewnçtrzny filtr 1 l 130 130 uv 250 250 uv 400 uv 86
- Navod k ponziti sera fil bioactive vnéjsi filtry 130 130 uv 250 250 uv 400 uv 92
- Bioactive di filtrelerin kullanim bilgileri i ix 130 130 uv 250 250 uv 400 uv 98
- Sera fil bioactive external filters 130 130 уф 250 250 уф 400 уф 104
- Инструкция по применению sera филь биоактив внешний фильтр 104
- Ене 109
Похожие устройства
- SERA Delta heater 25W Инструкция по эксплуатации
- SERA fil bioactive 11Вт 300л/ч Инструкция по эксплуатации
- SERA FP 750 Инструкция по эксплуатации
- SERA Fe-Test (железо), 15 мл Инструкция по эксплуатации
- SERA FP 350 Инструкция по эксплуатации
- SERA Cl-Test (хлор), 15 мл Инструкция по эксплуатации
- SERA AIR Plus 275л/ч Инструкция по эксплуатации
- SERA AIR Plus 110л/ч Инструкция по эксплуатации
- SERA AIR Plus 550л/ч Инструкция по эксплуатации
- SERA 8840 Инструкция по эксплуатации
- SERA Floredepot 2,4 кг Инструкция по эксплуатации
- SERA Nematol 10мл Инструкция по эксплуатации
- SERA Delta heater 100W Инструкция по эксплуатации
- SERA AQUA-TEST-BOX (рН, GH, KH, NH4/NH3, NO2, NO3, PO4, Fe, +Cl) Инструкция по эксплуатации
- SERA FLORE 2 FERRO, 50 мл Инструкция по эксплуатации
- SERA FLORE 1 CARBO, 500 мл Инструкция по эксплуатации
- SERA FLORE 1 CARBO, 50 мл Инструкция по эксплуатации
- SERA FP 150 Инструкция по эксплуатации
- SERA FP 100 Инструкция по эксплуатации
- SERA Delta heater 200W Инструкция по эксплуатации
It is advisable to change the filter media in the uppermost basket if there are many fine particles in the aquarium water Black sponge on top the white filter mat floss underneath This setup prevents the filter from clogging too quickly 4d Cleaning or changing the running unit of the sera fil bioactive 250 and 400 4 11 Lift off the filter head as described in 3d and 3e and put it on a table upside down 21 Pull out the locking bolt on the bottom side with a pair of tongs 4 1 1 3 Loosen the tube connection to the UV C lamp casing First pull the tube 4 1 21 out of the lamp casing to the left side Take off the tube connec tor 4 2 1 and the rotor chamber lid 4 2 2 If the rotor chamber lid does not come off to gether with the tube connector please loosen the rotor chamber lid 4 2 2 by turning it to the left and take it off 4 Carefully pull out the rotor with the shaft in a vertical line 4 3 1 The shaft 4 3 3 may become loose when pulling out the rotor This is no problem as the shaft Is removed for cleaning the rotor However the lower shaft locator and the separator disc 4 3 4 will remain lying at the bottom of the rotor chamber in this case You best turn over the filter head so the shaft loca tor and the separator disc will fall out in case the shaft remains stuck in the rotor remove the shaft locator and the separator disc on one side and pull the shaft out of the rotor 5 Clean the now empty tube 4 3 2 inside the fil ter head and the running tube with a bottle brush in case of damages at the shaft rotor or rubber shaft locators these must be replaced as to prevent consequential damage 3 Loosen the tube connection to the UV C lamp cas ing First pull the tube 6 1 2 out of the lamp cas ing to the left side 4 Loosen the screw on the locking 6 2 1 of the union nut 5 Unscrew the union nut 6 2 2 and take it off 6 Take off the glass protection cylinder 6 3 1 and the glass cylinder 6 3 2 and pull the UV C lamp out of the fixture 6 3 3 Reassemble in inverse order Please make sure the glass protection cylinder 6 3 1 properly locks in with the cut out in the edge at the bottom Make sure the two seal rings at the bottom end of the glass cylinder and all further parts are firmly In place Let an expert change the UV C lamp Changing the UV C lamp for the sera fil bioactive external filter 130 UV 7 Attention Pull power mains plug before you start Take the filter head off the filter 3d 3e Loosen the four screws on the bottom side of the filter head 7 1 and the two screws on the upper side 7 2 The upper and bottom parts are then separated while both parts remain linked by cable connections The clip lock han dles and the intake suction shaft may become loose They can easily be reinserted Cut the cable binder and pull the cable connector off the UV C lamp 7 3 Now screw off the big black ring on the UV C lamp holder 7 4 You can now easily take the UV C lamp with its cable out and insert a new lamp with cable Reassemble in inverse order 4e Cleaning or changing the running unit of the sera fil bioactive 130 5 1 Loosen the rotor chamber lid by turning it and take it off 5 1 2 Gently pull the rotor out of the rotor chamber 5 2 3 The shaft can also be pulled out afterwards First pull off the shaft locator on the rotor 5 2 1 Clean the now empty tube 5 2 2 inside the filter head and the running tube with a bot tle brush in case of damages at the shaft ro tor or rubber shaft locators these must be re placed as to prevent consequential damage Let an expert change the UV C lamp SAFETY PRECAUTIONS Avoiding water damages It is advisable to watch the filter closely for the first couple of days upon the installation as to make sure the hose connec tions are 100 water proof The sera fil bioactive external filter must be placed in a safe dry spot outside the aquarium just below the water surface level Never place the unit any low er than 1 5 m 60 in below the water surface level Do not submerge in water Operate filter only indoors Never operate without or without sufficient wa ter flow Disconnect this and all other electric devices from the power mains supply especially when working within the aquarium water or on the sera fil bioactive Protect the power mains plug against moisture and dripping water The sera fil bioactive external filter must be used only for the indicated purpose The temperature of the water to be pumped must not exceed 35 C 95 F The special sera UV C lamp may be operated only inside the sera fil bioactive UV external filter after it has been completely assembled according to these directions for use Every other use may lead to skin and eye damage Reassemble the filter In inverse order after you have finished maintenance Checking the UV C lamp The UV C lamp must be replaced if the control LED is not lit after switching on the UV C lamp Changing the UV C lamp for the sera fil bioactive external filters 250 UV 400 UV 6 Attention Pull power malns plug before you start 1 Take the filter head off the filter 3d 3e 2 Pull out the locking bolt on the bottom side with a pair of tongs 6 1 1 17