Maximum pressure 0.4 bar (5.8 psi.).
Always keep UV-C units and UV-C lamps out of the
reach of children!
Ensure that there is sufficient water flow through
the sera fil bioactive + UV external filter before
switching on the UV-C lamp. A minimum flow rate
must be ensured also during operation.
Too frequent “ON/OFF” switching reduces the life
expectancy of the UV-C lamp.
Ensure that the electrical plug of the switched-on
unit is freely accessible at all times.
Damage of the pump head, the cable or the plug
must not be repaired! In this case the filter must
immediately be disconnected from mains supply,
and must not be operated any more. This also ap-
plies in case of intended alterations of these
parts. This kind of damage must not be repaired
or mended. In case of damage or leakage at the fil-
ter canister, at the seals, or in the parts that con-
tain water, the filter must immediately been taken
apart and repaired.
The filter must be connected with a fault current
protection switch (RCD 30 mA).
Warning
1. Children should be supervised to ensure that they
do not play with the appliance.
2. This appliance is not intended for use by persons
(including children) with reduced physical, senso-
ry or mental capacities, or lack of experience and
knowledge, unless they have been given supervi-
sion or instruction concerning use of the appli-
ance by a person responsible for their safety.
3. If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
UV-C System
Wattage of the sera UV-C energy saving lamp:
130 + UV: 5 W
250 + UV, 400 + UV: 5 W
IPX4
18
Troubleshooting
Problem Possible cause Possible solution
Filter does not pump water Too much air inside the filter Use pump handle, if necessary
open and fill with aquarium water
by 3/4
No electrical supply Connect to power/mains supply
Rotor does not move Take off filter head and clean
Outlet valve is not open Throw multi-purpose handle (3.5)
Pump performance is very low Too much air inside the filter Use pump handle (3.10)
Filter is clogged Clean filter, if necessary replace
filter media with new ones
For units with UV-C lamp
Control LED is not lit No electrical supply Check plug
UV-C lamp is not properly
connected
Check cable connection
UV-C lamp faulty Replace lamp unit
Cloudiness/algae remain
unaffected
No bacterial cause, mineral
cloudiness
Clean or replace filter mat (floss)
and sponge, water change
UV-C lamp faulty/too old Replace lamp unit
Recommendations
Additionally secure all hose connections with
stainless steel hose clamps.
Always carry the filter by supporting the bottom.
Never lift it by the filter head, its external parts or
its hose connections.
Replace all hoses and the filter head seal every
2 years. Grease the filter head seal with Vaseline
every time before you close the filter.
Place the filter into a plastic bowl. Direct a hose
and cable loop into the bowl to avoid damage
caused by dripping water.
F
sera fil bioactive Außenf GBI INT:GBI sera fil bioactive INT 26.04.10 13:58 Seite 19

Содержание

Похожие устройства

Maximum pressure 0 4 bar 5 8 psi Always keep UV C units and UV C lamps out of the reach of children Ensure that there is sufficient water flow through the sera fil bioactive UV external filter before switching on the UV C lamp A minimum flow rate must be ensured also during operation Too frequent ON OFF switching reduces the life expectancy of the UV C lamp Ensure that the electrical plug of the switched on unit Is freely accessible at all times Damage of the pump head the cable or the plug must not be repaired in this case the filter must immediately be disconnected from mains supply and must not be operated any more This also ap plies in case of intended alterations of these parts This kind of damage must not be repaired or mended in case of damage or leakage at the fil ter canister at the seals or In the parts that con tain water the filter must Immediately been taken apart and repaired The filter must be connected with a fault current protection switch RCD 30 mA warning 1 Children should be supervised to ensure that they do not play with the appliance 2 This appliance is not intended for use by persons including children with reduced physical senso ry or mental capacities or lack of experience and knowledge unless they have been given supervi sion or instruction concerning use of the appli ance by a person responsible for their safety 3 if the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard UV C System Wattage of the sera UV C energy saving lamp 130 UV 5 W 250 UV 400 UV 5 W Troubleshooting Problem Possible cause Possible solution Filter does not pump water Too much air Inside the filter Use pump handle if necessary open and fill with aquarium water by 3 4 No electrical supply Connect to power mains supply Rotor does not move Take off filter head and clean Outlet valve is not open Throw multi purpose handle 3 5 Pump performance is very low Too much air Inside the filter Use pump handle 3 10 Filter is clogged Clean filter if necessary replace filter media with new ones No electrical supply Check plug UV C lamp is not properly connected Check cable connection For units with uv c lamp Control LED is not lit Cloudiness algae remain unaffected UV C lamp faulty Replace lamp unit No bacterial cause mineral cloudiness Clean or replace filter mat floss and sponge water change UV C lamp faulty too old Replace lamp unit Recommendations Replace all hoses and the filter head seal every 2 years Grease the filter head seal with Vaseline every time before you close the filter Place the filter into a plastic bowl Direct a hose and cable loop into the bowl to avoid damage caused by dripping water Additionally secure all hose connections with stainless steel hose clamps Always carry the filter by supporting the bottom Never lift It by the filter head its external parts or its hose connections 18

Скачать