Connection to electric mains
1. The heater is designed for connection to the single-phase ~220 V, 50Hz
electric mains equipped with a grounding loop.
2. Before connection, make sure that specifications of the electric mains
at the connection point meet the parameters indicated on the appliance
nameplate.
3. The heater should be connected to the electric mains using a cable with
wire section at least 1.5 mm
2
. The electric mains should be equipped with
an automatic circuit breaker with rated current not less than 16A.
4. For connection of the heater to the electric mains, it is necessary to do
the following:
remove the cover from the heater.
cut a hole in the rubber seal.
insert the electric cable to the heater.
tightly fix the bare ends of the electric cable in the junction block of the
heater with screws in strict correspondence with marking on the block.
reinstall the cover.
1. Before switching the heater, it is necessary to thoroughly wipe the
surface of the radiating boards first with a soft rag moistened in alcohol
and then with a dry rag in order to exclude appearance of burnt spots.
2. After switching and reaching the working mode, the appliance starts to
radiate infrared beams and heat the surrounding objects/bodies.
3. To exclude unpleasant burnt odor, it is recommended to keep the heater
clean preventing accumulation of dust on it.
1. During operation, it is necessary to periodically (once a year) check the
electric cable contacts and terminal connectors for good tightening.
2. If the body becomes dirty, wipe off dust with a towelette. Radiating
boards should be wiped in cold condition with alcohol.
7. OPERATION
8. MAINTENANCE
NOTE:
1. Depending on material and design of ceiling structural
elements, the heater is secured onto appropriate
fasteners chosen on basis of the strength condition.
Strength of the ceiling or structural elements, to which
the heater is secured, should be sufficient to endure
5-fold weight of the heater.
2. The heater can be installed on the wall and mounted
on the height not less than 1.8 from the floor. Also it
is obligatory to be installed an additional protection in
order to avoid the contact with heating plates.
NOTE:
The instruction manual for remote control block is not
included in the scope of delivery. Should be bought
separately.
NOTE:
Discoloration of paint on the heater body wall directed
to the ceiling during operation is not a defect. Changing
of colour for heating plates is not defect.
WARNING!
After installation of the heater and before switching for
the first time, it is necessary to wipe the radiating board
with alcohol. After that, it is PROHIBITED to touch the
radiating board.
WARNING!
Slight crackles may be heard during operation at the
moment of heating or cooling, which disappear, when
the heater reaches the working mode.