Timberk TAP FL 700 MF [5/24] Cleaning and maintenance instrument

Timberk TAP FL 700 MF [5/24] Cleaning and maintenance instrument
www.timberk.com • electric air purifier
5
• Low for silence technology
• Medium
for normal use
• High
for maximum cleaning
• Once the AUTO
is activated, appliance will automatically sense and
adjust the air clean speed once it detects pollutants in the air. Additionally
4 stages of clean sing, clearly shows your current air condition accordingly:
- Green: Clean
- Light Orange: Low pollution
- Orange: Medium pollution
- Red: High pollution
C) Operation with catalyst
Button «
» is used for switching the catalyst on and off (Symbol «UV+TIO2»
lights up).
This appliance combines advanced catalytic technologies to reduce
odors and chemical fumes from glues, solvents, and synthetic materials
when air passes through the filter and is activated by the internal UV LED.
(The catalyst system cannot be removed). If turned off, the appliance will
continue to filter particles from the air that passes through the filter but its
odor and VOC capability will be greatly reduced.
D) Timer
Using button «
» the operation time can be set-adjustable between 1~9
hours or continuous operation (circulated
), Sumbol J shows the operating
period that has been set (1h/2h/3h/4h/5h/6h/7h/8h/9h/ circulated
). The
display will automatically show the current value after a few seconds.
E) Night mode
By pressing the button «
» once, the night mode is switched on which
automatically dims the display brightness, appliance continue to operate
under with silence technology. If button «
» pressed again, the appliance
will no longer be in night mode.
F) Cleaning indicator
If red «CLEAN CELL» indicator appears on the display, the appliance should
be cleaned as recommended by the manufacturer. When the collector cell
is re-installed after cleaning, switch on the appliance and keep pressing
the button «
» at least 3 seconds until buzzer beeps, red «CLEAN CELL»
indicator goes out and «CLEAN CELL» timer is reset.
G) Catalyst indicator
7. CLEANING AND MAINTENANCE INSTRUMENT
Cleaning the Collector Cell
1.Unplug the appliance.
2.Open the front cover by gently pulling from the top comers.
3.Remove the collector cell by unlocking top and bottom knobs and pulling
straight out.
4.Separate the collector cell from the wire assembly for easier access to each
during cleaning.
5.Place each in sink, bathtub or other location where
cleaner can cover every surface.
6.Spray specialized cleaner between each cell plate and cover each surface.
Allow the cleaner to soak for a few minutes but do not let it dry. Thoroughly
rinse the collector cell with clean water.
An alternative method to clean the collector cell is
to rinse or soak it in warm water for loose debris. Mild liquid dish detergent
in water may also be used to help break down tough dirt and residue.
Thoroughly rinse the collector cell with clean water.
7.Place the collector cell under the sunlight to dry at
least 3 hours. Shake excess water from the collector cell to speed up drying
time. Do not use heated or compressed air to dry.
8.Reassemble the wire assembly and collector cell by inserting the post
located on the outside edges of the wire assembly into the recessed channels
of the collector cell. After guiding the post into the recessed channels, slide
the wire assembly until it locks into place.
H) Replace indicator
If red «REPLACE FILTER» indicator appears on the display, the VOC/
Formaldehyde filter should be replaced as recommended be the
manufacturer. When the VOC/Formaldehyde filter is reins – talled after
replacement, switch on the appliance and keep pressing the button «
» at
least 3 seconds until buzzer beeps, red «REPLACE FILTER» indicator goes
out and «REPLACE FILTER» timer is reset.
I) Fan speed indicator