Nibe F1255 [7/84] Delivery and handling

Nibe F1255 [7/84] Delivery and handling
Transport
F1255 should be transported and stored vertically in a
dry place. When being moved into a building, F1255
may be leant back 45 °. Note! Can be tail heavy.
TIP
The side panels can be removed for easier in-
stallation in the building.
R
0
R
0
Pulling out the cooling module
To simplify transport and service, the heat pump can
be separated by pulling the cooling module out from
the cabinet.
See page 58 for instructions about the separation.
Assembly
Position F1255 on a firm base that can take the
weight, preferably on a concrete floor or foundation.
Use the product's adjustable feet to obtain a horizont-
al and stable set-up.
30 - 50 mm
The area where F1255 is located must be equipped
with floor drainage.
Install with its back to an outside wall, ideally in a
room where noise does not matter, in order to elim-
inate noise problems. If this is not possible, avoid
placing it against a wall behind a bedroom or other
room where noise may be a problem.
Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
Installation area
Leave a space of 800 mm in front of the product. Ap-
prox 50 mm free space is required in order to open the
side hatches. The hatches do not need to be opened
during service, all service on F1255 can be carried out
from the front. Leave space between the heat pump
and wall behind (and any routing of supply cables and
pipes) to reduce the risk reproduction of any vibration.
(50) (50)

* A normal installation needs 300 - 400 mm (any side) for connec-
tion equipment, i.e. level vessel, valves and electrical equipment.
5Chapter 2 | Delivery and handlingNIBE™ F1255