Model 187 & 189
Getting Started
14
Setup Selections
The meter allows you to change the default operating
configuration of the meter by changing setup options
made at the factory. Many of these setup options affect
general meter operations and are active in all functions.
Others are limited to one function or group of functions.
To enter the Setup mode, turn the meter on and press
O T (SETUP). In the Setup mode, each press of
O T (SETUP) saves changes to the last selection
and steps to the next option.
Each setup option appears in the primary display in the
sequence shown in Tables 4 and 5.
The options in Table 4 are available only when the
preconditions are met. The options in Table 5 are
available for all functions. (When measuring dc volts,
none of the preconditions in Table 4 are required, and
only the selections shown in Table 5 will appear.)
To exit the Setup mode, Press O N (CANCEL).
Be sure to save your last selection by pressing O T
first.
Table 4. Function Specific Setup Selections
Selection Precondition Option Choices (
) Factory Default
000.0 °C
or
000.0 °F
Temperature (
w )
selected.
Temperature
offset adjust
000.0 ° to ± 100.0 °C (180.0 °F) - Use q to
increment or decrement digit.
Use to select digit. Selected digit
flashes.
000.0 °C (or °F)
L Int Model 189 only. Log interval
MM:SS - Use
q to increment or decrement
minute or second values.
Use to select minute or seconds.
Selected values flash.
15:00
dbrEF AC volts (\ or
,) selected.
dB type dBm or dBV (m or V flashing) - Use
to
select.
dBV
dbrEF AC volts (\ or
,) and dBm
selected.
dBm reference 0001 Ω to 1999 Ω - Use q to increment or
decrement digit.
Use to select digit.
0600 Ω
Содержание
37- Model 187 189 true rms multimeter
- Model 187 189
- Getting started
- True rms multimeter
- Lifetime limited warranty
- Title page
- Table of contents
- True rms multimeter
- Safety information
- Introduction
- Contacting fluke
- Warning
- Warning
- Caution
- Pushbuttons
- Rotary switch
- You can show all display segments as shown in figure 1 by pressing while turning the meter on release to turn off the full display
- Understanding the display
- True rms multimeter understanding the display
- Figure 1 display features
- Display features are shown in figure 1 and described in table 3 major display features are described in the users manual
- Warning
- Fast min max avg
- Dbm dbv
- Nf µ f mf
- Hz khz mhz
- A ma µ a
- Setup selections
- Safety and compliances
- Feature summary
- Physical specifications
- Basic specifications
- Detailed accuracy specifications
- Ω up to
- Frequency counter sensitivity
- Burden voltage a ma µa
- Input characteristics
Похожие устройства
-
Fluke 15b+Инструкция РУС -
Fluke 28 IIИнструкция по эксплуатации -
Fluke 87V с поверкойИнструкция по эксплуатации -
Fluke 106 с поверкойИнструкция по эксплуатации -
Fluke 117Extended Specs -
Fluke 117Информация о калибровке -
Fluke 117Дополнение к информации о калибровке -
Fluke 117Положение об энергозависимости памяти -
Fluke 116СРуководство по эксплуатации -
Fluke 116Руководство по эксплуатации -
Fluke 116Информация о калибровке -
Fluke 116Add wireless to your Fluke digital multimeter
Узнайте, как изменить настройки измерительных приборов для оптимальной работы. Пошаговое руководство по входу в режим настройки и сохранению изменений.