Fubag B4000B/100H СМ3 [8/20] Operator s manual
Содержание
- Cover 1 1
- Operator s manual 1
- Инструкция по эксплуатации 1
- Operator s manual 2
- Page01 2
- Page02 3
- Page03 4
- Operator s manual 5
- Page04 5
- Page05 6
- Operator s manual 7
- Page06 7
- Safety operation 7
- Not to do 8
- Operator s manual 8
- Page07 8
- Operator s manual 9
- Page08 9
- Start up and use 9
- Technical specifications 9
- Maintenance 10
- Operator s manual 10
- Page09 10
- Operator s manual 11
- Page10 11
- Troubleshooting 11
- Hydraulic tests of receiver 12
- Operator s manual 12
- Page11 12
- Warranty 12
- Page12 13
- Гиьад 13
- Инструкция по эксплуатации 13
- Правила безопасности 13
- Page13 14
- Гиоад 14
- Запрещается 14
- Инструкция по эксплуатации 14
- Page14 15
- Инструкция по эксплуатации 15
- Технические характеристики 15
- Page15 16
- Гирад 16
- Инструкция по эксплуатации 16
- Пуск и эксплуатация 16
- Page16 17
- Инструкция по эксплуатации 17
- Техническое обслуживание 17
- Шрад 17
- Page17 18
- Инструкция по эксплуатации 18
- Неисправности и способы их устранения 18
- Page18 19
- Гарантийные обязательства 19
- Гидравлические испытания ресивера 19
- Гиьад 19
- Инструкция по эксплуатации 19
- Cover 2 20
Похожие устройства
- Fubag B4000B/50H СМ3 Инструкция по эксплуатации
- Фиолент МСУ10-13-РЭ Инструкция по эксплуатации
- Фиолент МСУ9-16-2РЭ КЕЙС Инструкция по эксплуатации
- Mystery MGM-2000 white Руководство по эксплуатации
- Fubag VDC/50 CM3 Инструкция по эксплуатации
- Mystery MEK-1627 black Руководство по эксплуатации
- Mystery MEK-1620 white/grey Руководство по эксплуатации
- Mystery MEK-1627 white Руководство по эксплуатации
- Aiken MG 2500 M Инструкция по эксплуатации
- Aiken MG 6500 M Инструкция по эксплуатации
- Akai КU-1072X Инструкция по эксплуатации
- Akai KS-1070O Руководство по эксплуатации
- Engy GН30-W Инструкция по эксплуатации
- Energy EN-237 Инструкция по эксплуатации
- Energy EN-603 Инструкция по эксплуатации
- Leonord LE-1009 1800Вт Инструкция по эксплуатации
- Ergomax ER 3400 Инструкция по эксплуатации
- Russian Engineering Group GG7200-X Инструкция по эксплуатации
- Maxwell MW-1024 Инструкция по эксплуатации
- Maxwell MW-1046 Инструкция по эксплуатации
Fubag Operator s manual www fubag ru Not to do A Never direct the jet of air towards persons animals or your body Always wear safety goggles to protect your eyes from flying objects that may be lifted by the jet Never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor Never use the appliance in your bare feet or with wet hands or feet Never pull the power cable to pull the plug out of the socket or to move the compressor Never leave the appliance exposed to adverse weather conditions rain sun fog snow Never transport the compressor with the reservoir pressurized Never weld or machine the reservoir In the case of faults or corrosion replace it completely Never allow inexpert persons to use the compressor Keep children and animals away from the work area Never position flammable or nylon or fabric articles close to and or on the compressor Never clean the compressor with flammable liquids or solvents Clean with a damp cloth only after making sure that you have unplugged the compressor The compressor is designed only to compress air and must not be used for any other type of gas The compressed air produced by the compressor cannot not be used for pharmaceutical food or hospital purposes except after particular treatments It is not suitable for filling the air bottles of scuba divers Never use the compressor without guards belt guard and never touch moving parts To avoid overheating of the electric motor this compressor is designed for intermittent operation as indicated on the dataplate forexample S3 50 means 5 minutes ON and 5 minutes OFF In the case ofoverheating the thermal cutout of the motor trips automatically cutting off the power when the temperature is too high due to excess current takeoff To facilitate machine restart it is important not only to carry out the operations indicated but also to set the button of the pressure switch returning this to the OFF position and then ON again figures 1 a 1 b Press the reset button on the terminal box of themotor fig 2 Are fitted with a pressure switch equipped with a delayed closing air vent valve orwith a valve located on the check valve that facilitates motor start up therefore a few second jet of airfrom this with the reservoir empty is to be considered normal To guarantee machine safety all the compressors are fitted with a safety valve that is activated in the case of failure of the pressure switch fig 4 When connecting an air powered tool to a hose of compressed air supplied by the compressor interruption of the flow of airfrom the hose is compulsory Use of the compressed air for the various purposes envisaged inflation air powered tools painting washing with water based detergents only etc requires knowledge of and compliance with the rules established for each individual use 7