Fubag B4000B/100H СМ3 [9/20] Start up and use

fubag Operator s manual www fubag ru 2 Technical specifications MODEL VCF 50 CM3 Power kW Tank I Pressure bar Air displacement l min Volt Hz Size mm Weight kg 2 2 50 10 440 220 50 830x360x740 50 VCF 100 CM3 2 2 100 10 440 220 50 1050x420x850 71 B4000B 50 CM3 B4000B 50H CM3 2 2 50 10 400 220 50 830x360x720 46 B4000B 100 CM3 B4000B 100H CM3 2 2 100 10 400 220 50 1050x420x850 66 B5200B 100 CT4 3 100 10 530 380 50 1050x420x850 68 MODEL Power kW Tank I Pressure bar Air displacement l min Volt Hz Size mm Weight kg B5200B 200 CT4 B6800B 100 CT5 B6800B 200 CT5 B6800B 270 CT7 5 B10000B 270 CT11 3 4 4 200 10 530 380 50 1500x520x950 115 100 10 690 380 50 1050x450x950 75 200 10 690 380 50 1500x520x990 126 5 5 270 7 5 270 10 850 380 50 1450x585x1260 175 10 1050 380 50 1450x585x1260 200 The manufacturer reserves himself the right to make the manual s content or function change without any preliminary notification of the users 3 Start up and use Fit the wheels and foot or the caster wheel for models that are fitted with this according to the instructions provided in the packaging For versions with fixed feet assemble the front bracket kit or the vibration dampers if furnished Check that the rating data match the effective characteristics of the system voltage and power Check for correspondence between the compressor plate data with the actual specifications of the electrical system A variation of 10 with respect of the rated value is allowed Check that all screws tab 1 Check that belt deflection tab 3 Check the oil level using the sight glass and if necessary unscrew the vent plug and top up figures 6a 6b Insert the power plug in a suitable socket checking that the button of the pressure switch located on the compressor is in the O OFF position figures 5a 5b 5c 5d At this point the compressor is ready for use Operating on the switch of the pressure switch or the selector for versions with electric panel figures 5a 5b 5c 5d the compressor starts pumping air in the reservoir through the delivery hose The absence of pressure in the head facilitates subsequent restart When air is used the compressor restarts automatically when the lower calibration value is reached approx 2 bar between upper and lower The pressure inside the reservoir can be checked on the gauge provided fig 4 The compressor continues to operate automatically with this work cycle until the position of the switch of the pressure switch figures 5a 5b 5c 5d is modified To use the compressor again wait at least 10 seconds after this has been switched off before restarting Only the wheel mounted compressors are fitted with a pressure reducer in the versions with fixed feet it is usually installed on the use line Air pressure can be regulated in order to optimize use of air powered tools operating on the knob with the valve open pulling it up and turning it in a clockwise direction to increase pressure and counterclockwise to reduce this fig 7 Once you have set the value required push the knob down to lock it 8

Скачать