Timberk TEC.PF3 LE 1500 Инструкция по эксплуатации онлайн [6/20] 331314

Содержание

Похожие устройства

O IMPORTANT The electric outlet must be rated for not less than 10A electric cable with a strand with cross section not less than 3x1 5 mm2 for copper 7 CONTROL OF THE CONVECTOR TEC PF3 M IN series convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display TEC PF3 M IN series control panel Fig 8 1 heating indicator light It is illuminated when the unit s heating is on 2 Thermostat handle It is used to set the desired room temperature 3 Ionizer switch Ionizer It is used to switch on off the air ionizing function 4 Two button switch with display It is used to select the following heating power modes I mode low power II mode medium power III mode high power indicator lights of both buttons will be illuminated 3 Set temperature 3 1 Temperature can be set within the range 5 to 30 C 3 2 Turn the thermostat handle clockwise to the stop to position max at that if room temperature is below the set one then the heating indicator light must be illuminated When the room temperature reaches the desired level turn the thermostat handle counterclockwise until the unit is switched off the heating indicator light will go out Now the thermostat will maintain the set temperature switching on and off the convector from time to time During especially cold weather the convector may not be able to provide the required room heating In this case set the thermostat to the level somewhat higher than the desired one 4 Antifreeze mode Turn the thermostat handle counterclockwise to position min The thermostat will automatically switch on heating of the convector if the room temperature goes below 5 C and the unit is connected to electric mains and the heating mode is on 5 Comfort mode Comfort mode which can be selected by means of the thermostat handle corresponds to the most comfortable room temperature 6 Air ionizing function The convector is equipped with an air ionizer 6 1 You can switch on and off the air ionizer by means of the ionizer switch ion located on the control panel 6 2 Ionizer switch illumination lights up when the air ionizer is switched on 6 3 The air ionizer is a completely independent device and can operate even when the unit s heating mode is off NOTE A small static electric charge may be accumulated on metal surfaces of a case in units equipped with an air ionizer If your electric main has no grounding circuit or it is damaged In this case there is a small possibility of electric shockfrom static voltage O Operation of TEC PF3 M IN series convector 1 Switch on the convector Connect the convector to electric mains by plugging the power cord into an electric outlet 2 Select the heating power 2 1 Press button 1 to select the low heating power at that the indicator light of button will be illuminated 2 2 Press button 2 to select the medium heating power at that the indicator light of button 2 will be illuminated 2 3 Press button 1 and 2 to select the high heating power at that 6 www timberk com electric convector heater IMPORTANT I If the unit is operated without a grounding circuit or it is damaged it is not recommended to switch on and operate the air ionizer O 7 Switch off the convector Set the buttons of the heating power mode selector to position 0 and disconnect the unit from electric mains

Скачать