Timberk TEC.PF3 LE 1500 Инструкция по эксплуатации онлайн [6/20] 331314
Содержание
- Timberk 1
- Модели models 1
- Руководство по эксплуатации instruction manual 1
- English 3
- Iiiiiiiiiiii 3
- Control panel 2 outlet grill louver 3 unit s case front part 4 cold air inlet 5 support legs 4
- Convector with a bracket and a carrying handle 1 pc 2 bracket s mounting screw 4 pcs 3 dowel 4 pcs 4 support leg 2 pcs 5 mounting screw of a support leg 8 pcs 6 operation manual 1 pc 7 guarantee card 1 pc 8 packing 1 pc 4
- Description of the convector fig 4
- Overall dimensions of the convector as per fig are given in table 2 table 2 4
- Scope of delivery 4
- Technical characteristics technical characteristics of the convector are given in table 1 table 1 4
- To improve products quality design and technical characteristics of the convector as well as its scope of delivery may be altered by the manufacturer without prior notification 4
- English 5
- English 7
- Llllllllllllllllllll 7
- English 9
- Русский 11
- Быстрая самоокупаемость за счет высокого кпд и скорости набора задаваемой температуры 5 простота установки надежность в эксплуатации и легкость обслуживания 6 трехрежимный нагревдля экономии электроэнергии 7 встроенный ионизатор воздуха 8 опорные ножки для установки конвектора в любом удобном месте 9 встроенная ручка для перемещения 10 встроенный датчик падения отключит конвектор если он будет отклонен от вертикального положения например если прибор 12
- Конвекторы в линейке лтьегк разделяются по максимально 12
- Отличаются друг от друга длиной прибора при равных значениях высоты и глубины стандартная габаритная высота всех приборов равна 400 мм данная схема построения габаритных размеров позволяет потребителю использовать конвекторы лгльегк разных мощностей в одном помещении рядом друг с другом не нарушая при этом привычных симметрий и идеально вписывая несколько 12
- Потребляемой мощности нагревательного элемента и в этом 12
- Прибороводновременно в созданный вами интерьер 12
- Размеры конвекторов в зависимости от мощности рис 12
- Рис 1 12
- Рис 2 12
- Случайно опрокинут при использовании на ножках 12
- Технические характеристики технические характеристики конвектора приведены в таблице 1 таблица 1 12
- Русский 13
- Llllllllllllllllllll 15
- Русски 15
- Русский 17
- Timberk 20
Похожие устройства
- Timberk TEC.PS1 EL 10 IN (RB) Инструкция по эксплуатации
- Fubag IN 206 LVP Инструкция по эксплуатации
- Fubag IWS234/680 100111 Инструкция по эксплуатации
- Барс Profi MIG-507 DT2 Инструкция по эксплуатации
- AEG WKL 503 S Инструкция по эксплуатации
- Stiebel Eltron CS 20 Инструкция по эксплуатации
- Metabo Basic 250-24 W (601533000) Инструкция по эксплуатации
- AEG WKL 753 S Инструкция по эксплуатации
- Барс Profi ARC-187 D Инструкция по эксплуатации
- AEG WKL 1003 S Инструкция по эксплуатации
- Stiebel Eltron CNS 75 S Инструкция по эксплуатации
- Stiebel Eltron CNS 50 S Инструкция по эксплуатации
- Stiebel Eltron CNS 150 SE Инструкция по эксплуатации
- Stiebel Eltron CNS 100 S Инструкция по эксплуатации
- Stiebel Eltron CNS 150 S Инструкция по эксплуатации
- Stiebel Eltron CNS 50 SE Инструкция по эксплуатации
- Stiebel Eltron CNS 200 S Инструкция по эксплуатации
- Stiebel Eltron CNS 100 SE Инструкция по эксплуатации
- Stiebel Eltron CNS 250 S Инструкция по эксплуатации
- Stiebel Eltron CNS 100 F Инструкция по эксплуатации
O IMPORTANT The electric outlet must be rated for not less than 10A electric cable with a strand with cross section not less than 3x1 5 mm2 for copper 7 CONTROL OF THE CONVECTOR TEC PF3 M IN series convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display TEC PF3 M IN series control panel Fig 8 1 heating indicator light It is illuminated when the unit s heating is on 2 Thermostat handle It is used to set the desired room temperature 3 Ionizer switch Ionizer It is used to switch on off the air ionizing function 4 Two button switch with display It is used to select the following heating power modes I mode low power II mode medium power III mode high power indicator lights of both buttons will be illuminated 3 Set temperature 3 1 Temperature can be set within the range 5 to 30 C 3 2 Turn the thermostat handle clockwise to the stop to position max at that if room temperature is below the set one then the heating indicator light must be illuminated When the room temperature reaches the desired level turn the thermostat handle counterclockwise until the unit is switched off the heating indicator light will go out Now the thermostat will maintain the set temperature switching on and off the convector from time to time During especially cold weather the convector may not be able to provide the required room heating In this case set the thermostat to the level somewhat higher than the desired one 4 Antifreeze mode Turn the thermostat handle counterclockwise to position min The thermostat will automatically switch on heating of the convector if the room temperature goes below 5 C and the unit is connected to electric mains and the heating mode is on 5 Comfort mode Comfort mode which can be selected by means of the thermostat handle corresponds to the most comfortable room temperature 6 Air ionizing function The convector is equipped with an air ionizer 6 1 You can switch on and off the air ionizer by means of the ionizer switch ion located on the control panel 6 2 Ionizer switch illumination lights up when the air ionizer is switched on 6 3 The air ionizer is a completely independent device and can operate even when the unit s heating mode is off NOTE A small static electric charge may be accumulated on metal surfaces of a case in units equipped with an air ionizer If your electric main has no grounding circuit or it is damaged In this case there is a small possibility of electric shockfrom static voltage O Operation of TEC PF3 M IN series convector 1 Switch on the convector Connect the convector to electric mains by plugging the power cord into an electric outlet 2 Select the heating power 2 1 Press button 1 to select the low heating power at that the indicator light of button will be illuminated 2 2 Press button 2 to select the medium heating power at that the indicator light of button 2 will be illuminated 2 3 Press button 1 and 2 to select the high heating power at that 6 www timberk com electric convector heater IMPORTANT I If the unit is operated without a grounding circuit or it is damaged it is not recommended to switch on and operate the air ionizer O 7 Switch off the convector Set the buttons of the heating power mode selector to position 0 and disconnect the unit from electric mains