Biasi Parva Control 32SV Инструкция по эксплуатации онлайн [17/30] 338187
Содержание
- Iiiihiiiihihiiiiiiih 1
- Zh biasi 1
- Maintenance 5
- Описание котла 5
- Calibrate the gas valve according to the 6
- Conversion kit indicating the type of gas and the gas pressures to which the appliance has been set 6
- Extract the control panel as explained 6
- Gas conversion 6
- Gas supply используемый газ 6
- Hand side panel and the front panel of the case 6
- Heating output required see section 6 in this manual 6
- In accordance with the following table 6
- In the section 5 1 of this manual 6
- Instructions given in the section 6 6
- Loosen the screws a and remove the 6
- Natural gas метан l p g сжиженый газ 6
- Of the combustion chamber and the removable case of the sealed chamber 6
- Panel adjacent to the data badge the self adhesive label included with the 6
- Position of dip switch n положение переключателя n 2 on вкл off выкл 6
- Re assemble the burner the front panel 6
- Replace the service panel the left 6
- Service panel fig 7 6
- Set correctly the dip switch 2 fig 7 6
- Set the correct gas pressure for central 6
- Stick on the inside of the left hand side 6
- Table of contents 6
- Выберите правильное давление для 6
- Герметичной камеры 6
- Извлеките панель управления как описано в разделе 5 1 настоящего руководства 6
- Калибруйте газовый клапан в 6
- Левой боковой панели расположив 6
- Мощности см раздел 6 настоящего руководства 6
- Наклейку поставлется с 6
- Ослабьте винты а и снимите сервисную панель рис 7 6
- Панель левую боковую панель и 6
- Переднюю панель корпуса 6
- Переключатель 2 рис 7 в 6
- Правильно установите 6
- Преобразовательным комлектом с 6
- Приведенными в разделе 6 6
- Приклейте с внутренней стороны 6
- Рядом с табличкой с данными 6
- Содержание 6
- Соответствии с инструкциями 6
- Соответствии со следующей 6
- Таблицей 6
- Требуемой выходной тепловой 6
- Указанием типа газа и давлением на которое был настроен котел 6
- Установите на место горелку переднюю панель камеры сгорания и сьемную переднюю часть 6
- Установите на место сервисную 6
- Gas conversion 7 выбор газа 1 appliance description 1 описание устройства 7
- Air flue exhaust sampling points 8
- Точки отбора всасываемого воздуха и отвода отходящих газов 8
- О о о 9
- Ойй 9
- Instruction for use 10
- Инструкция no 10
- Эксплуатации 10
- Useful advice 3 полезные советы 6 commissioning 6 ввод в эксплуатацию 16
- Technical information 4 техническая информация 20
- Installation 30
- Монтаж 30
Похожие устройства
- Alphatherm Beta ATE 100 Инструкция по эксплуатации
- Alphatherm Beta ATE 100 Буклет
- Biasi Parva Control 32SV Технические характеристики
- Biasi Parva Control 32SV Сертификат
- Biasi Nova Parva 24A Инструкция по эксплуатации
- Biasi Nova Parva 24A Технические характеристики
- Biasi Nova Parva 24A Сертификат
- Biasi Nova Parva 28A Инструкция по эксплуатации
- Biasi Nova Parva 28A Технические характеристики
- Biasi Nova Parva 28A Сертификат
- Biasi Nova Parva 24S Инструкция по эксплуатации
- Biasi Nova Parva 24S Технические характеристики
- Biasi Nova Parva 24S Сертификат
- Biasi Nova Parva 28S Инструкция по эксплуатации
- Biasi Nova Parva 28S Технические характеристики
- Biasi Nova Parva 28S Сертификат
- Biasi Nova Parva 32S Инструкция по эксплуатации
- Biasi Nova Parva 32S Технические характеристики
- Biasi Nova Parva 32S Сертификат
- Biasi PARVA COMFORT 24A Инструкция по эксплуатации
Installation Useful advice 5 13 Only C h boiler 5 13 Котел для отопления The boiler is fitted to operate with a storage tank If the boiler Isn t connected to the starage tank fit the setting jumpers on the main control p c b as indicaded in Fig 5 23 Котел предназначен также для работы с накопительным бойлером Если котел не подключен к накопительному бойлеру установите переключатели главного блока управления в положение как указано на рис 5 23 Чтобы установить переключатели отключите котел от электросети To set the setting jumpers isolate the boiler from the mains electricity supply During the service the most important components of the boiler will be inspected and cleaned This service can be part of a maintenance contract In particular you are advised to have the following checks carried out primary heat exchanger domestic hot water storage tank накопительный воды burner горелки exhaust fume duct and flue системы отвода дымохода pressurisation of the expansion tank герметичность бака filling up of the central heating circuit заполнение системы отопления bleeding of air from the central heating system развоздушивание отопления general check of the appliance s operation выполнить котла бойлер для горячей отходящих общую газов и расширительного системы проверку работы 3 4 External cleaning 3 4 Внешний уход Before doing out any cleaning disconnect the appliance from the electrical mains using the fused spur isolation switch fitted adjacent to the appliance To clean the external panels use a cloth soaked in soapy water Do not use solvents abrasive powders or sponges Do not carry out cleaning of the appliance and or its parts with readily flammable substances for example petrol alcohols naphtha etc Прежде чем производить какие либо работы по очистке котла отключите его от электросети посредством выключателя расположенного рядом с котлом Чтобы очистить наружные панели используйте тряпку смоченную в мыльном растворе Не используйте растворители абразивные порошки и губки Ни в коем случае не используйте для чистки котла и или его частей легковоспламеняющиеся жидкости например бензин спирт и т п 3 5 Operational faults 3 5 Неисправности If the lock out signal lamp comes on this indicates that the safety lock out 5 Fig 3 2 has stopped the boiler Если загорается индикатор блокировки это означает что сработала блокировка безопасности 5 рис 3 2 и остановила работу котла Чтобы снова запустить котел необходимо нажать кнопку повторного включения котла 6 рис 3 2 При первом запуске котла и последующих процедурах по обслуживанию газопровода возможно будет необходимо произвести несколько раз перезапуск котла чтобы удалить воздух из трубопроводов Если во время работы котла слышен шум воздушных пузырьков To re start the boiler it is necessary to press the boiler reset button 6 Fig 3 2 For the first lighting up and following maintenance procedures for the gas supply it may be necessary to repeat the resetting operation several times so as to remove the air present in the pipework If noises due to air bubbles are heard during operation 38 В процессе обслуживания будут осмотрены и очищены наиболее важные детали котла Такой сервис должен быть предусмотрен в договоре не сервисное обслуживание В особенности мы рекомендуем произвести следующий контроль первичного теплообменника 11