APPLICATION OF QUICK CONNECTORS (OPTIONAL)
The quick disconnect feature is used when installing the flexible interconnecting hose through a window or a wall. It
enables temporary separation between indoor and outdoor units when passing the hose through and opening in an
external wall.
DISCONNECTING THE UNITS (See Figures 10 and 11)
WARNING: Make sure to disconnect the unit from power supply.
STEP 1.
STEP 2.
STEP 3.
STEP 4.
STEP 5.
STEP 6.
STEP 7.
STEP 8.
Unscrew the fastening screw (2) and remove cover (1).
Unplug the electrical plug (3) and pull it out from its socket (4).
Disconnect drain hose (9) from the drain pan connector (10)
Remove the tube clamp (12) by unscrewing its fastening screw.
Unscrew the liquid line quick disconnect (5) from its mating part (6) as follows:
- Retain lock-nut (13) with the supplied wrench No. 2 (20) and open with the supplied wrench No. 1 (19) the
hexagonal nut (5).
- Slowly turn nut (5), and open until part (5) is disconnected from part (6).
Unscrew the suction line quick disconnect (7) from its mating part (8)as follows:
- Retain lock-nut (14) with the supplied wrench No. 2 (20) and open with the supplied wrench No 1 (19) the
hexagonal nut (7).
- Slowly turn nut (7), and open until part (7) is disconnected from part (8).
Remove interconnecting hose clamp (21) by unscrewing its fastening screw.
To protect the tube openings from any foreign material or contamination, close them with the provided plugs
11. insert plug (16) into nut (5) , plug (18) into nut (7), Cover (15) onto
part (6) and cover (17) on part (8). Tighten all of these lightly.
AND COVERS; REFER TO FIGURE
To disconnect between the indoor and outdoor unit, perform the following steps:
The outdoor unit, together with the interconnecting flexible hose (11) may now be separated from the indoor unit,
and the hose can be passed through the wall opening.
English 8
Figure 11
Figure 10
STEP 8
STEP 6
STEP 2
STEP 3
STEP 4
STEP 1
STEP 7
STEP 5
Содержание
- Mobile split air conditioner 2
- Contents 3
- If your air conditioner is for cooling only please disregard the instructions related to heating 4
- Important notes 4
- In this manual 4
- Introduction 4
- Please read these instructions before operating the air conditioner 4
- Description 5
- Accessories 6
- Installation 7
- Installation of outdoor unit see figure 6 7 8 8
- Application of quick connectors optional 10
- Disconnecting the units see figures 10 and 11 10
- After locating outdoor and indoor unit in their respective places perform the following steps to reconnect between the two units 11
- Connect quick disconnect 5 to its mating part 6 as follows turn by hand part 5 onto part 6 retain lock nut 13 with the supplied wrench no 2 20 and close with the supplied wrench no 1 19 the hexagonal nut 5 to its mating part 6 until it is tight 11
- Connecting the units see figures 12 and 13 11
- Electrical connection 11
- Remove protection plugs 16 18 and covers 15 17 from their respective connectors see figure 13 11
- Step 1 11
- Step 2 11
- Step 3 11
- Step 4 11
- Step 5 11
- Step 6 11
- Step 7 11
- Step 8 11
- Warning 11
- Modes of operation functions and features 13
- Operation electronic model with remote control 13
- Use of wireless remote control 15
- On unit indicators and controls electronic modes see figure 15 16
- On unit operation 16
- Operation procedure see figs 15 16 18
- Select the cooling mode by pressing mode button 2 switch to the desired fan speed or to auto fan by pressing button 3 select suitable temperature setting 18
- This operation starts at the highest airflow in order to quickly lower the room temperature it will then automatically switch to low air flow in order to quietly maintain the selected temperature 18
- Automatic vertical air swing 19
- Dry operation 19
- Heating operation 19
- Heating operation with auto fan mode 19
- Selecting the temperature 19
- Current clock time set 20
- Sleep function 20
- Timer operation 20
- Turning off the air conditioner 20
- Timer operating modes 21
- Operation for mechanical models 22
- Operating procedure 23
- Care and maintenance 24
- Moving and storing all models 25
- Important notices 26
- Before calling for service 27
Похожие устройства
- Ammari AM-138-90 Инструкция по эксплуатации
- Ammari AM-137-90 Инструкция по эксплуатации
- Ammari AM-134-90 Инструкция по эксплуатации
- Ammari AM-136-90 Инструкция по эксплуатации
- Ammari AM-138-100 Инструкция по эксплуатации
- Ammari AM-088-100 Инструкция по эксплуатации
- Ammari AM-139-100 Инструкция по эксплуатации
- Airwell Westherm 35 Инструкция по эксплуатации
- Airwell Westherm 35 Технические характеристики
- Ammari AM-136-100 Инструкция по эксплуатации
- Ammari AM-115 L Инструкция по эксплуатации
- Ammari AM-115 R Инструкция по эксплуатации
- Airwell Westherm 45 Инструкция по эксплуатации
- Airwell Westherm 45 Технические характеристики
- Airwell Westherm 50 Инструкция по эксплуатации
- Airwell Westherm 50 Технические характеристики
- Airwell Westherm 55 Инструкция по эксплуатации
- Airwell Westherm 55 Технические характеристики
- Airwell Westherm 65 Инструкция по эксплуатации
- Ammari AM-089 R Инструкция по эксплуатации
Скачать
Случайные обсуждения