Airwell Westherm 35 [7/16] Dimensional data and weight of options
![Airwell Westherm 55 [7/16] Dimensional data and weight of options](/views2/1408117/page7/bg7.png)
Page 6
5 - Dimensional Data and Weight of Options
Component description
V : Vertical mounting unit heater.
H : Horizontal mounting unit heater.
A : Cubic inlet casing for matching other accessories on 3
faces.
B : Mixing box with dampers.
C : Horizontal non-return shutter.
D : Vertical non-return shutter.
E : Filter box with flat-bank filter.
F : External weatherproof louvre with bird guard.
G : Duct.
J : Mixing box with adjustable shutter and wire mesh
guard.
K : Return air plenum with wire mesh guard.
L : Flat-bank filter for casing A.
Z : Roof air inlet with bird guard and seal ring, to be
mounted by others.
Sizes354550556570110
a
440 560 560 680 800 800 680
e
370 490 490 610 730 730 610
f
382 502 502 622 742 742 622
f
1
392 512 512 632 752 752 632
h
720 900 900 1080 1280 1280 1080 *
h
2
190 230 230 275 310 310 275
h
4
960 1080 1080 1200 1320 1320 1200
j
480 600 600 720 840 840 720
j
1
460 580 580 700 820 820 700
Dimensions (mm)
Note : The size 110 is equipped with 2 accessory sets of the
size 55. (* 1080 x 1870).
a 500
e x e
a x a
a
E
a x a
120
a x a
f x f
f1 x f1
j
a x a
120
a
E
j
1
Arrangement 1 (VAL) Arrangement 2 (VAF) Arrangement 3 (VAK)
Filter removal Filter E is optional Filter E is optional
The filter box E allows a filter removal from one of the four sides.
j
a x a
120
a
E
j
1
1440
or 940
a x a
Arrangement 5 (VAGK)
Filter E is optional
j
a x a
120
a
E
j
1
1440
or 940
a x a
f1 x f1
a x a
f x f
Arrangement 6 (VAGJF)
Filter E is optional
j
a x a
120
a
E
j
1
a x a
f1 x f1
a x a
f x f
Arrangement 4 (VAJF)
Filter E is optional
Standard arrangements
Содержание
- Westherm 35 110 1
- Description p 4 2
- Dimensional data and weight of options p 7 2
- Dimensional data and weight of standard units p 5 2
- Electrical connections p 14 2
- English 2
- Installation p 9 2
- Introduction p 3 2
- Maintenance p 15 2
- Preliminary checks before start up p 15 2
- Safety precautions p 3 2
- Table of contents 2
- Water connections p 12 2
- Caution 3
- Introduction 3
- Safety precautions 3
- The manufacturer warranty will not be applied if all installation instructions stated in this manual have not been followed 3
- Warning 3
- Description 4
- Electrical data 4
- English 4
- Inspection and storage 4
- Operating limits 4
- Standard motor data 4
- Unit in operation with hot water circulation 4
- Diffuser vm 5
- Diffuser vn 5
- Diffuser vr 5
- Dimensional data and weight of standard units 5
- Vertical arrangement 5
- Diffuser hn 6
- Diffuser ho 6
- Diffuser hp 6
- Dimensional data and weight of standard units cont d 6
- English 6
- Horizontal arrangement 6
- Arrangement 1 val arrangement 2 vaf arrangement 3 vak 7
- Arrangement 4 vajf 7
- Arrangement 5 vagk 7
- Arrangement 6 vagjf 7
- Component description 7
- Dimensional data and weight of options 7
- Dimensions 7
- Standard arrangements 7
- Arrangement 10 vabdf 8
- Arrangement 11 habgz 8
- Arrangement 12 habcgz 8
- Arrangement 7 vagz 8
- Arrangement 8 vabgz arrangement 9 vabf 8
- Dimensional data and weight of options cont d 8
- English 8
- Position of damper control shaft 8
- Standard arrangements 8
- Installation 9
- Unit handling 6 installation location 9
- Warning 9
- English 10
- Installation cont d 10
- Installation instructions 10
- Warning 10
- 55 fan speed 11
- C 10 c 15 c 20 c 30 c 11
- Correction factor 11
- Factor 1 8 1 0 0 0 0 0 0 0 11
- For other temperature differences use the correction factor 11
- Installation cont d 11
- Supply air throw m 11
- Supply diffuser for a supply air temperature difference of 15 c 11
- Temp difference 11
- The air throw allows the units to be installed in the room 11
- The air throw of a propeller fan unit heater is the distance between the unit and the points where the air velocity is no longer felt by the human body approx 0 m sec 11
- The table below gives the air throw of a unit in relation to model and 11
- Vertical arrangement horizontal arrangement 11
- English 12
- Warning 12
- Water coil connections 12
- Water connections 12
- Water volume in the coils 12
- Water connections cont d 13
- Water pressure drop 13
- Electrical connections 14
- English 14
- Standard wiring diagram 14
- To perform electrical wiring of fan motor please refer to wiring diagram supplied in the motor terminal box 14
- Unit connection 14
- Warning 14
- Air filter optional 15
- Caution 15
- Electrical connections 15
- Fan motor assembly 15
- Maintenance 15
- Page 14 15
- Preliminary checks before start up 15
- Vaf arrangement 15
- Val arrangement 15
- Water piping system 15
- Ace pons industrie 42 cours jean jaurès 17800 pons france 16
Похожие устройства
- Airwell Westherm 35 Технические характеристики
- Ammari AM-136-100 Инструкция по эксплуатации
- Ammari AM-115 L Инструкция по эксплуатации
- Ammari AM-115 R Инструкция по эксплуатации
- Airwell Westherm 45 Инструкция по эксплуатации
- Airwell Westherm 45 Технические характеристики
- Airwell Westherm 50 Инструкция по эксплуатации
- Airwell Westherm 50 Технические характеристики
- Airwell Westherm 55 Инструкция по эксплуатации
- Airwell Westherm 55 Технические характеристики
- Airwell Westherm 65 Инструкция по эксплуатации
- Ammari AM-089 R Инструкция по эксплуатации
- Ammari AM-089 L Инструкция по эксплуатации
- Ammari AM-100-80 LOW Инструкция по эксплуатации
- Ammari AM-100-80 Инструкция по эксплуатации
- Airwell Westherm 65 Технические характеристики
- Airwell Westherm 70 Инструкция по эксплуатации
- Ammari AM-A-025-80 Инструкция по эксплуатации
- Airwell Westherm 70 Технические характеристики
- Airwell Westherm 110 Инструкция по эксплуатации