Airedale UCFC 160 [31/46] Ultima compact freecool chillers

Airedale UCFC 125 [31/46] Ultima compact freecool chillers
ULTIMA COMPACT FREECOOL Chillers
Chillers
30
Installation & Maintenance : 903-132 IM E 06/05/A
Commissioning Data
WATERSIDE PRESSURE DROPS
(20% Ethylene Glycol Concentration)
CAUTION
Constant water flow MUST be maintained. Variable water volume is NOT
recommended and may invalidate warranty.
UCFC160D - UCFC450D
WATERSIDE PRESSURE DROP
(
kPa
)
0
50
100
150
200
250
300
5 101520253035
160-180D
275D
250D
225D
200D
300D
330-360D
400D
450D
WATERFLOW (l/s)
UCFC160DQ -
UCFC450DQ
WATERSIDE PRESSURE DROP
(
kPa
)
0
50
100
150
200
250
300
5 101520253035
160DQ-180DQ
400DQ
330DQ-360DQ
300DQ
275DQ
250DQ
225DQ
200DQ
450DQ
WATERFLOW (l/s)