Beko FSS52130DCRS [14/96] Installation and connection

Содержание

Похожие устройства

Follow below steps In the picture to secure the safety chain to your product Cooker stability chain for cookers is not designed with bracket engagement slot Room ventilation All rooms require an openable window or equivalent and some rooms will require a permanent vent as well The air for combustion is taken from the room air and the exhaust gases are emitted directly into the room Good ventilation is essential for safe operation of your appliance Rooms with doors and or windows which open directly to the outer environment The doors and or windows that open directly to the outer environment must have a total ventilation opening of the dimensions specified in the table below which is based on the total gas power of the appliance total gas power consumption of the appliance is shown in the technical specification table of this user manual If the doors and or windows do not have a total ventilation opening corresponding to the total gas consumption of the appliance as specified in the table below then there must definitely be an additional fixed ventilation opening in the room to ensure that the total minimum ventilation requirements for the total gas consumption of the appliance is achieved The fixed ventilation opening can include openings for existing airbricks extraction hood ducting opening dimension etc 14 EN Total gas consumption kW min Ventilation opening cm2 0 2 2 3 100 3 4 4 6 175 300 6 8 400 120 8 10 500 10 11 5 600 11 5 13 700 13 15 5 800 15 5 17 900 17 19 1000 19 24 1250 Rooms that do not have openable doors and or windows that open directly to the outer environment If the room where the appliance is installed does not have a door and or a window that opens directly to the outer environment other products shall be sought that definitely provide a fixed nonadjustable and nonclosable ventilation opening which meets the total minimum ventilation opening requirements for the total gas consumption of the appliance as indicated in the above table Also the appropriate building regulations advise should be followed Where a room or internal space contains more than one gas appliance additional ventilation area shall be provided on top of the requirement given in the table above Size of additional ventilation area shall be appropriate to regulations of other gas appliances There should also be a minimum clearance of 10mm on the bottom edge of the door that opens to the inner environment in the room where the appliance is installed You must ensure that items such as carpets and other floorcoverings etc do not affect the clearance when the door is closed The cooker may be located in a kitchen kitchen diner or a bed sitting room but not in a room containing a bath or a shower The cooker must not be installed in a bed siting room of less than 20m3 Do not install this appliance in a room below ground level unless it is open to ground level on at least one side Installation and connection Product can only be installed and connected in accordance with the statutory installation rules

Скачать