Beko CE 58100 [38/72] Covered terminal block

Содержание

In models with zz covered terminal block In mix models a cable supplied with a plug with your oven H05 V V F 3G 1 5 mm2 If a cable without a plug is provided together with your oven H05 V V F 3G 2 5 mm2 Take care to connect as below Brown cable L Live Blue cable N Neutral Green Yellow cable E Earth If your oven is supplied without supply cord use schema 1 to choose supply cord and use schema ll for installation of cord The cable length should be max 2m long for isolation safety Schema II Open the terminal block cover 1 Connect the supply cable according to wiring diagram on the rear covt Adjacent side walls above the Assembly the terminal block cover to its place appliance must not be nearer v The mains cable must pass through the cable clamp 2 Fix the supply cable to main body with to the cooker than 150 mm two screw via cable tightener Your oven is suitable for single and three phase connection 2 and should be of heat resistant material Leave at least 750 The mains cable should be routed away from the appliance and in mm clearance above the particular ventilation slots the vent outlet and should not be obstructed when hotplates The appliance should be pushed in to position between the appliance and the wall and or cabinet located on a level surface Connection Type Voltage Monophase 220 230 Three phase Two phase with Neutral with Neutral 380 400 415 V 380 400 415 V The two front feet can be adjusted as required To 240 V ensure that your appliance is standing level adjust the two Supply cord type 3x2 5 mm2 5x2 5 mm2 4x2 5 mm2 front feet by turning clockwise max 2m long H05 V V F H05 V V F H05 V V F or counterclockwise until the product is in firm contact with the floor 4