F- THINGS THAT MUST BE DONE BEFORE CALLING AUTHORIZED
SERVICE
Troubleshooting
The falures and solutons stated n ths secton can be performed easly by yourselves and always consult to an
Authorzed Uğur Servce f these suggestons do NOTE solve your problem.
Troubleshooting Possible Solution Result.
Cooler is NOTE working. (No sound
or only fan sound comes from the
product.)
It may be due to the thermostat
NOTE plugged in. The fuse may be
blown or broken down.
Condenser lamella may be ob-
structed or get dirty.
It will run again when reached to
the suitable temperature.
Insert the plug properly.
Consult to an Authorized Uğur Ser-
vice or a competent electrician.
Clean the condenser lamellas.
Device internal temperature is high. External ambient temperature is
very high or wrong thermostat
setting.
Very close to the back wall, ventila-
tion shutters are obstructed or it’s
front is prevented.
It may have been expose to exces-
sive external wind.
Condenser lamellas are very dirty.
Move the cooler to a place where
the external temperature is lower.
Adjust to the stated gap.
Clean in front of the ventilation
shutters.
Prevent the wind.
Clean the condenser lamellas.
Device internal temperature is very
low.
Wrong internal thermostat setting. Re-set the thermostat.
High degree of sweating on the
glass and inside the device.
Water discharge hole may be
obstructed when sweating is seen
inside the cabin.
In glass sweating on the other hand,
current external ambient humidity
is over 65%.
Clean water discharge hole. With re-
gards to the high humidity, you can
move your cooler to an environment
with less humidity.
Bad smell coming from the bottom
part of the cooler.
Lower water discharge tray is dirty. Clean the water discharge tray.
CAUTION!
Interventon to any falure that may occur n your product must be carred out by Authorzed Uğur
Servce.
Any nterventon that may be done by you may harm you, your employee or customer, nvaldate the
product guarantee and cause materal damage (fre etc..).
In case of any falure, consult to Uğur Customer Care or Authorzed Uğur Servce. (see Page 20)
Setting the digital thermostat values other than the factory settings are completely under the
user's responsibility. Our company shall NOTE be held responsible for the material and moral
losses that may arise in connection thereto.
Digital thermostat failures
Alarm sgnals for Dxel thermostat;
Alarm sgnals for Carel thermostat;
Setting the digital thermostat values other than the factory settings are completely under the
user's responsibility. Our company shall NOTE be held responsible for the material and moral
losses that may arise in connection thereto.
MESSAGE REASON PROCEEDINGS TO BE FOLLOWED
P1 Room sensor failure Check the sensor connection
P2 sen Evaporator sensor failure Check the sensor connection before replacing the sensor.
HA pa- Maximum temperature alarm Check compressor operation and relevant parameter values.
LA pa- Maximum temperature alarm Check compressor operation and relevant parameter values.
EA External alarm Alarm stops automatically when digital entry is deactivated.
MESSAGE REASON PROCEEDINGS TO BE FOLLOWED
EO Control sensor 1 failure
(Control)
Check the sensor
E1 Control sensor 2 failure
(Defrost)
Check the sensor and d0=0/1/4,F0=1
E2 Control sensor 3 failure
(Condenser)
Check the sensor and whether it is (A4=10)
IA External alarm Check external alarm outlets or A4 and A7 parameters.
dOr Open door alarm Check that the door is closed or A4 and A7 parameters.
LO Low temperature alarm Alarm will be turned-o automatically when the temperature
returns to the set value range. Also check the set value.
HI High temperature alarm Alarm will be turned-o automatically when the temperature
returns to the set value range. Also check the set value. Check
whether the cooling system runs properly.
EE/Eer Unit parameter failure Check the parameters.
EF Operating parameter failure Check dT,dP and d4 parameters; defrost eect. Alarm will be closed
automatically when defrost operation nishes.
ED Defrost completed out of
its time
dT, dP ve d4 parametrelerini; defrost etkisini kontrol et. Defrost
ilemi normal olarak bittiğinde alarm kapanacaktır.